MAX5965BEAX+ Maxim Integrated Products, MAX5965BEAX+ Datasheet - Page 38

IC PSE CTRLR FOR POE 36SSOP

MAX5965BEAX+

Manufacturer Part Number
MAX5965BEAX+
Description
IC PSE CTRLR FOR POE 36SSOP
Manufacturer
Maxim Integrated Products
Type
Power Over Ethernet Controller (PoE)r
Datasheet

Specifications of MAX5965BEAX+

Applications
IP Phones, Power over LAN, Network Routers and Switches
Internal Switch(s)
No
Voltage - Supply
2.4 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
36-BSOP (0.300", 7.5mm Width)
Product
PoE / LAN Solutions
Supply Voltage (max)
60 V
Supply Voltage (min)
32 V
Power Dissipation
1388.9 mW
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Input Voltage
60V
Supply Current
4.8mA
Digital Ic Case Style
SSOP
No. Of Pins
36
Uvlo
28.5V
Frequency
400kHz
Filter Terminals
SMD
Interface
I2C
Rohs Compliant
Yes
Controller Type
Power Supply
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
High-Power, Quad, Monolithic, PSE Controllers
for Power over Ethernet
Enable 2-event classification for a port by setting the corre-
sponding ENx_CL6 bit (Table 25). When the bit is enabled,
the classification cycle will be repeated three times at
21.3ms intervals. The device keeps the output voltage
around -9V between each cycle. The repetition of the clas-
sification cycles enables discovering of class 6 PDs. The
ENx_CL6 bit is active only in auto- or semi-mode.
Note: Performing three consecutive classifications in
manual mode is not the same as performing 2-event
classification in semi or auto mode.
Set EN_WHDOG (R1Fh[7]) to 1 to enable the watchdog
function. When activated, the watchdog timer counter,
WDTIME[7:0], continuously decrements toward zero
once every 164ms. Once the counter reaches zero
(also called watchdog expiry), the MAX5965A/
MAX5965B enter hardware-controlled mode and each
port shifts to a mode set by the HWMODE_ bit in regis-
ter R1Fh (Table 27). Use software to set WDTIME
(Table 26) and continuously set this register to some
nonzero value before the register reaches zero to pre-
Table 25. SMODE and 2-Event Enable Register
Table 26. Watchdog Register
38
EN4_CL6
EN3_CL6
EN2_CL6
EN1_CL6
SMODE4
SMODE3
SMODE2
SMODE1
WDTIME
SYMBOL
SYMBOL
______________________________________________________________________________________
ADDRESS = 1Ch
ADDRESS = 1Eh
BIT
7
6
5
4
3
2
1
0
BIT
7
6
5
4
3
2
1
0
CoR or
R/W
CoR
CoR
CoR
CoR
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Port 4 2-event classification enabled
Port 3 2-event classification enabled
Port 2 2-event classification enabled
Port 1 2-event classification enabled
Port 4 hardware control flag
Port 3 hardware control flag
Port 2 hardware control flag
Port 1 hardware control flag
WDTIME[7]
WDTIME[6]
WDTIME[5]
WDTIME[4]
WDTIME[3]
WDTIME[2]
WDTIME[1]
WDTIME[0]
Enable the SMODE function (Table 25) by setting
EN_WHDOG (R1Fh[7]) to 1. The SMODE_ bit goes high
when the watchdog counter reaches zero and the
port(s) switch over to hardware-controlled mode.
SMODE_ also goes high each and every time the soft-
ware tries to power on a port, but is denied since the
port is in hardware mode. A reset sets R1Ch = 00h.
vent a watchdog expiry. In this way, the software grace-
fully manages the power to ports upon a system crash
or switchover.
While in hardware-controlled mode, the MAX5965A/
MAX5965B ignore all requests to turn the power on and
the flag SMODE_ indicates that the hardware has taken
control of the MAX5965A/MAX5965B operation. In addi-
tion, the software is not allowed to change the mode of
operation in hardware-controlled mode. A reset sets
R1Eh = 00h.
DESCRIPTION
DESCRIPTION

Related parts for MAX5965BEAX+