Datasheet

Specifications of ICB2FL01G

Frequency
20 ~ 120 kHz
Current - Supply
4.2mA
Voltage - Supply
10.6 V ~ 17.5 V
Operating Temperature
-25°C ~ 125°C
Package / Case
DSO-19
Packages
PG-DSO-19
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Lead Free Status / Rohs Status
 Details
Other names
SP000363741

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICB2FL01G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
HSGD Low Voltage
HSGD High Voltage
HSGD active Shut Down
HSGD Peak Source Current
HSGD Peak Sink Current
HSGD Rise Time
HSGD Fall Time
1)
Delay Timer 1
Delay Timer 2
Inverter Time
Inverter Dead Time Max
Inverter Dead Time Min
∆ Inverter Dead Time Max
∆ Inverter Dead Time Min
Min. Duration of Ignition
Max. Duration of Ignition
Duration of Pre – Run
Voltage at RTPH Pin
Voltage at RTPH Pin
Voltage at LVS1 / LVS2 Pin
Voltage at RES Pin
Voltage at RFPH Pin
Voltage at RFRUN Pin
Voltage at V
Voltage at RES Pin
1) Tolerance for this voltage is: ± 5%
Datasheet
The Parameter is not Subject to Production Test – verified by Design / Characterization
5.3.3.7
5.3.3.8
5.3.3.9
Parameter
CC
Pin
High Side Gate Drive (HSGD)
Timer Section
Built in Customer Test Mode
I
2
V
V
V
T
HSGDSource
Symbol
T
I
t
t
t
t
HSGDSink
t
t
V
V
t
t
NOIgnition
HSGDHigh
HSGDASD
HSGDRise
nd
DeadMax
DeadMax
t
V
V
V
HSGDLow
PRERUN
HSGDFall
DeadMin
DeadMin
TIMER1
TIMER2
V
V
Ignition
RFRUN
V
LVS1,2
t
RTPH
RTPH
RFPH
Inv
RES
RES
CC
Generation FL-Controller for FL-Ballasts
Page 51 of 56
> 14.1
- 200
- 200
Min.
- 0.4
0.02
0.05
2.25
140
100
197
565
0.5
9.7
7.8
1.0
5.0
5.0
5.0
20
70
74
34
0
0
0
0
Limit Values
0.05
- 0.2
10.5
0.22
1.25
typ.
- 50
300
220
100
130
625
V
V
V
1.1
2.5
35
84
40
V
V
V
V
V
1)
1)
1)
max.
Preheating Time = 0ms (Skipped Preheating)
IC remains in Preheating
Disables Lamp Voltage Sense
Disable the Filament Detection
Built in Customer Test Mode - Clock
Acceleration. Decreasing Time for the
following Procedures.
Preheating by Factor 4
Timeout Ignition by Factor 2
Pre RUN by Factor 15
EOL by 60
- 0.05
11.2
2.75
300
160
160
200
200
236
685
0.1
2.5
0.5
1.5
70
94
48
Unit
mA
mA
ms
ms
ms
ms
ms
ns
ns
µs
µs
µs
ns
ns
V
V
V
V
V
V
I
I
I
V
I
V
I
V
I
R
R
2V < V
R
8V > V
R
For Lamp Detection
For V
HSGD
HSGD
LSGD
HSGD
HSGD
HSGD
CCHS
CCHSOFF
CCHS
Load
Load
Load
Load
Test Condition
= - 20mA (source)
= - 1mA (source)
= 10Ω+C
= 10Ω+C
= 10Ω+C
= 10Ω+C
= - 20mA (source)
= 5mA (sink)
= 100mA (sink)
= 20mA (sink)
BUS
=15V
=5V
LSGD
LSGD
+ 0.3V
> 95%
< 8V
> 2V
ICB2FL01G
Load
Load
Load
Load
= 1nF
= 1nF
= 1nF
= 1nF
V1.2