TLE6288R Infineon Technologies, TLE6288R Datasheet - Page 17

IC SW SMART MULTICHAN PDSO36

TLE6288R

Manufacturer Part Number
TLE6288R
Description
IC SW SMART MULTICHAN PDSO36
Manufacturer
Infineon Technologies
Type
High Side/Low Side Driverr
Datasheet

Specifications of TLE6288R

Input Type
SPI
Number Of Outputs
6
On-state Resistance
350 mOhm
Current - Output / Channel
2A
Current - Peak Output
3.6A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-36
Switch Type
High Side/Low Side
Power Switch Family
TLE 6288 R
Power Switch On Resistance
150mOhm
Mounting
Surface Mount
Supply Current
10mA
Package Type
DSO
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Propagation Delay Time
200ns
Pin Count
36
Power Dissipation
800mW
Packages
PG-DSO-36
Channels
6.0
Output Current
2.0
Rds (on)
150 mOhm
Quiescent Current (max.)
0,05 mA
Operating Range
6.0 - 16.0 V
For Use With
DEMOBOARDTLE6288RIN - BOARD DEMO FOR TLE 6288R
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
SP000013727
TLE6288RNT
TLE6288RT
TLE6288RT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6288R
Manufacturer:
SIE
Quantity:
5 510
Part Number:
TLE6288R
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Electrical Characteristics: SPI Timing (cont’d)
V
ground, positive current flowing into pin (unless otherwise specified)
Pos.
5.2.10
5.2.11
1) Not subject to production test, specified by design.
2) To get the correct diagnostic information, the transfer delay time has to be extended to the maximum fault filter time
5.3
As soon as a fault occurs for longer than the fault filter time, the fault information is latched into the diagnosis
register (and the Fault pin will change from high to low state). A new error on the same channel will overwrite the
old error report. Serial data out pin (SO) is in a high impedance state when CS is high. If CS receives a LOW signal,
all diagnosis bits can be shifted out serially. If the sent command was valid (see Note in
edge of CS will reset the diagnosis registers (except the channel OT flag) and restart the fault filter time. In case
of an invalid command the device will ignore the data bits and the diagnosis register will not be reset at the rising
CS edge.
Figure 9
For Full Diagnosis there are two diagnostic bits per channel configured as shown in
Diagnosis bit 0 and bit 1 are always set to 1.
Data Sheet
CC
t
f(fault)max
= 4.5 V to 5.5 V,
Parameter
Transfer Delay Time
(CS high time between two
accesses)
Data Valid Time
C
C
L
L
= 200 µs.
= 50 pF to 100 pF
= 220 pF
Diagnostic Serial Data Out SO
SPI Diagnostics
Two Bits per Channel Diagnostic Feedback plus two Overtemperature Flags
MSB
15
Ch.6
HH
HL
LH
LL
14
T
j
= -40 °C to +150 °C,
13
1)
Ch.5
2)
12
Normal function
Overload, Shorted Load or Overtemperature
Open Load
Switch Bypassed
11
Ch.4
10
Symbol
t
t
dt
valid
V
9
Ch.3
B
= 6 V to 16 V, Reset = H,
Channel Overtem-
perature Flag
8
Min.
200
17
Ch.2
7
Limit Values
Typ.
6
Ch.1
5
Bit0 and Bit1
is always 1
Max.
120
150
4
V
DO
3
=
Unit Pin/
ns
ns
2
V
CC
Figure
, all voltages with respect to
IC Overtem-
perature Flag
Comment
1
LSB
Chapter
0
Rev. 2.4, 2007-08-08
9.
Conditions
5.5) the rising
TLE6288R
SPI