TLE6214L Infineon Technologies, TLE6214L Datasheet - Page 10

no-image

TLE6214L

Manufacturer Part Number
TLE6214L
Description
IC SWITCH DUAL CURR SENSE PDSO12
Manufacturer
Infineon Technologies
Type
Low Sider
Datasheet

Specifications of TLE6214L

Input Type
SPI
Number Of Outputs
2
On-state Resistance
180 mOhm
Current - Output / Channel
6.5A
Current - Peak Output
12A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-12
Packages
PG-DSO-12
Thermal Class
Heatslug down
Id Nom
2 x 2 A
Pin Count
12.0 Pins
Channels
2.0
Comment
please use RoHS compliant TLE8102SG
For Use With
DEMOBOARDTLE6214LIN - BOARD DEMO FOR TLE 6214L
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
SP000014123
TLE6214LNT
TLE6214LT
TLE6214LT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6214L
Manufacturer:
INF
Quantity:
5 510
Part Number:
TLE6214L
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
4. Reset Registers : Sets back all internal registers. Logic registers to default and Fault registers to no
error.
Default settings after Reset:
5. Sleep mode : Activates the low quiescent mode. In sleep mode only the command “wake up” is
valid. Other commands will not lead to any reactions. Wake up is done by the Wake Up command or by
undervoltage reset.
6. Wake Up : Deactivates the low quiescent mode. A specified time (t
fully functional.
7. Channels on / off : Turns on / off the power outputs (if configured for serial control)
After activation of the low quiescent mode by the “sleep” command, the outputs are turned off and the
serial control register is set to default values.
8. No Command : No valid command and will not lead to an reaction (register value change, switching
channels, ...) of the IC. After Chip Select giong L!H the diagnosis register will not be reset.
SPI Diagnostics:
As soon as a fault occurs for longer than the fault filtering time (exept Overtemperature; no filtering
time), the fault information is latched into the diagnosis register (and the Fault pin will change from high
to low state). A new error on the same channel will over-write the old error report. Serial data out pin
(SO) is in a high impedance state when CS is high. If CS receives a LOW signal, all diagnosis bits can
be shifted out serially. If the sent command was valid the rising edge of CS will reset all diagnosis reg-
isters and restart the fault filtering time. In case of an invalid command the device will ignore the data
bits and the diagnosis register will not be reset at the rising CS edge.
V3.0
Ch1 : Serial control bit of channel 1
Ch2 : Serial control bit of channel 2
0: Output off(default)
1: Output on
0: Output off(default)
1: Output on
Parallel Input control
Autorestart
Status Outputs ST1 and ST2 active
Current Limit 2
Channel ON/OFF register “OFF”
Slew rate fast
Page
10
wake
) after this command the IC is
Datasheet TLE 6214 L
18.10.2004

Related parts for TLE6214L