TLE6214L Infineon Technologies, TLE6214L Datasheet - Page 22

no-image

TLE6214L

Manufacturer Part Number
TLE6214L
Description
IC SWITCH DUAL CURR SENSE PDSO12
Manufacturer
Infineon Technologies
Type
Low Sider
Datasheet

Specifications of TLE6214L

Input Type
SPI
Number Of Outputs
2
On-state Resistance
180 mOhm
Current - Output / Channel
6.5A
Current - Peak Output
12A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-12
Packages
PG-DSO-12
Thermal Class
Heatslug down
Id Nom
2 x 2 A
Pin Count
12.0 Pins
Channels
2.0
Comment
please use RoHS compliant TLE8102SG
For Use With
DEMOBOARDTLE6214LIN - BOARD DEMO FOR TLE 6214L
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
SP000014123
TLE6214LNT
TLE6214LT
TLE6214LT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6214L
Manufacturer:
INF
Quantity:
5 510
Part Number:
TLE6214L
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Datasheet TLE 6214 L
Edition 2004-06-08
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
81669 München, Germany
© Infineon Technologies AG 2004.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as a guarantee of
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest In-
fineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the fail-
ure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life sup-
port devices or systems are intended to be implanted in the human body, or to support and/or maintain and sus-
tain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons
may be endangered.
Page
22
18.10.2004
V3.0