AMIS30623C623BRG ON Semiconductor, AMIS30623C623BRG Datasheet - Page 22

IC MOTOR DRIVER/CTLR 32-QFP

AMIS30623C623BRG

Manufacturer Part Number
AMIS30623C623BRG
Description
IC MOTOR DRIVER/CTLR 32-QFP
Manufacturer
ON Semiconductor
Datasheet

Specifications of AMIS30623C623BRG

Applications
Stepper Motor Driver
Number Of Outputs
1
Current - Output
800mA
Voltage - Supply
6.5 V ~ 29 V
Operating Temperature
-40°C ~ 165°C
Mounting Type
Surface Mount
Package / Case
32-VSQFP
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS30623C623BRG
Manufacturer:
ON Semiconductor
Quantity:
1 850
Part Number:
AMIS30623C623BRG
Manufacturer:
ON Semiconductor
Quantity:
10 000
is received (this valid frame can be addressed to another
slave).
Thermal Shutdown Mode
<SoftStop> command and goes to motor shutdown
mode (see Figure 14: State Diagram Temperature
Management).
The circuit will return to normal mode if a valid LIN frame
When thermal shutdown occurs, the circuit performs a
− <Tinfo> = “00”
− <TW> = ‘0’
− <TSD> = ‘0’
− <Tinfo> = “01”
− <TW> = ‘0’
− <TSD> = ‘0’
Normal Temp.
Low Temp.
T° < Tlow
T° > Tlow
T° < Ttw &
LIN frame:
GetStatus or
GetFullStatus
Figure 14. State Diagram Temperature Management
T° > Ttw
T° > Ttw
− <Tinfo> = “10”
− <TW> = ‘1’
− <TSD> = ‘0’
− <Tinfo> = “00”
− <TW> = ‘1’
− <TSD> = ‘0’
− <Tinfo> = “00”
− <TW> = ‘1’
− <TSD> = ‘1’
− Motor shutdown
Thermal warning
http://onsemi.com
(motion disabled)
Post thermal
Post thermal
shutdown 2
warning
22
T° < Ttw
Temperature Management
thresholds and one shutdown level, as illustrated in the state
diagram and illustration of Figure 14: State Diagram
Temperature Management below. The only condition to
reset flags <TW> and <TSD> (respectively thermal warning
and thermal shutdown) is to be at a temperature lower than
Ttw and to get the occurrence of a GetStatus or a
GetFullStatus LIN frame.
The AMIS−30623 monitors temperature by means of two
T° < Ttw
T° > Ttsd
T° > Ttw
T° > Ttsd
− <Tinfo> = “11”
− <TW> = ‘1’
− <TSD> = ‘1’
−SoftStop if
− Motor shutdown
− <Tinfo> = “10”
− <TW> = ‘1’
− <TSD> = ‘1’
− Motor shutdown
Thermal shutdown
motion ongoing
(motion disabled)
(motion disabled)
Post thermal
shutdown 1
T° < Ttsd

Related parts for AMIS30623C623BRG