MC15XS3400CPNAR2 Freescale Semiconductor, MC15XS3400CPNAR2 Datasheet - Page 30

no-image

MC15XS3400CPNAR2

Manufacturer Part Number
MC15XS3400CPNAR2
Description
IC SWITCH HIGH SIDE QUAD 24-QFN
Manufacturer
Freescale Semiconductor
Type
High Side Switchr
Datasheet

Specifications of MC15XS3400CPNAR2

Number Of Outputs
4
Rds (on)
15 mOhm
Internal Switch(s)
Yes
Current Limit
5A
Voltage - Input
6 ~ 20 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
24-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FAULT MODE
driving the
fault condition is removed, except for over-current, severe
short-circuit, over-temperature and under-voltage which will
be reset by a new turn-on command (each fault_control
signal to be toggled).
available (and reset) via the SO pin during the first valid SPI
communication.
30
15XS3400
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
The 15XS3400 is in Fault mode when:
• V
• wake-up = 1,
• fail = X,
• fault=1.
This device indicates the faults below as they occur by
• Over-temperature fault,
• Over-current fault,
• Severe short-circuit fault,
• Output(s) shorted to VPWR fault in OFF state,
• Open load fault in OFF state,
• Over-voltage fault (enabled by default),
• Under-voltage fault.
The
Fault information is retained in the SPI fault register and is
PWR
FS
pin will automatically return to logic [1] when the
FS
and V
pin to logic [0] for RST input is pulled up:
DD
are within the normal voltage range,
SPI register without effect on the corresponding output state
(HS[x]) and the
START-UP SEQUENCE
following sequence is provided:
set to logic [1]) with an external reference clock:
function is not guaranteed.
The Open load fault in ON state is only reported through
The 15XS3400 enters in Normal mode after start-up if
•VPWR and VDD power supplies must be above their
•generate wake-up event (wake-up=1) from 0 to 1 on
And, in case of the PWM module is used (PWM_en bit is
•apply PWM clock on IN0 input pin after maximum 200 μs
If the correct start-up sequence is not provided, the PWM
under-voltage thresholds,
RSTB. The device switches to Normal mode with SPI
register content is reset (as defined in
Table
after 50 μs typical and all SPI registers are set to default
values (set to logic [0]). The UV fault is reported in the
SPI status registers.
(min. 50 μs).
23). All features of 15XS3400 will be available
FS
pin.
Analog Integrated Circuit Device Data
Freescale Semiconductor
Table 11
and

Related parts for MC15XS3400CPNAR2