MAX16066ETL+ Maxim Integrated Products, MAX16066ETL+ Datasheet - Page 22

no-image

MAX16066ETL+

Manufacturer Part Number
MAX16066ETL+
Description
IC SYSTEM MANAGER 8CH 40-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16066ETL+

Applications
Power Supply Monitor, Sequencer
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN Exposed Pad, 40-HVQFN, 40-SQFN, 40-DHVQFN
Number Of Voltages Monitored
8
Undervoltage Threshold
2.7 V
Manual Reset
Resettable
Watchdog
Yes
Battery Backup Switching
No
Power-up Reset Delay (typ)
200 us
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Supply Current (typ)
10 mA
Maximum Power Dissipation
2105 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Chip Enable Signals
No
Internal Hysteresis
Yes
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
When GPIO1
pose inputs/outputs, read values from the GPIO_ ports
through r1Eh and write values to GPIO_s through r3Eh.
Note that r3Eh has a corresponding flash register, which
programs the default state of a general-purpose output.
See Table 11 for more information on reading and writing
to the GPIO_.
Table
Table
22
REGISTER
REGISTER
ADDRESS
ADDRESS
_____________________________________________________________________________________
1Eh
3Eh
3Fh
40h
11. GPIO_ State Registers
12. GPIO_ Configuration Registers
GPIO8 are configured as general-pur-
ADDRESS
ADDRESS
FLASH
FLASH
23Eh
23Fh
240h
BIT RANGE
BIT RANGE
[2:0]
[5:3]
[7:6]
[3:1]
[6:4]
[0]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
GPIO1 configuration
GPIO2 configuration
GPIO3 configuration (LSB)
GPIO3 configuration (MSB)
GPIO4 configuration
GPIO5 configuration
GPIO6 configuration (LSB)
GPIO1 input state
GPIO2 input state
GPIO3 input state
GPIO4 input state
GPIO5 input state
GPIO6 input state
GPIO7 input state
GPIO8 input state
GPIO1 output state
GPIO2 output state
GPIO3 output state
GPIO4 output state
GPIO5 output state
GPIO6 output state
GPIO7 output state
GPIO8 output state
GPIO1
puts, Fault1 or Fault2. Fault outputs can assert on one or
more overvoltage, undervoltage, or early warning condi-
tions for selected inputs, as well as the secondary over-
current comparator. Fault1 and Fault2 dependencies are
set using registers r36h to r3Ah. See Table 14. When
a fault output depends on more than one MON_, the
fault output asserts when one or more MON_ exceeds a
programmed threshold voltage. These fault outputs act
independently of the critical fault system, described in
the Critical Faults section.
GPIO8 are configurable as dedicated fault out-
DESCRIPTION
DESCRIPTION
Fault1 and Fault2