MAX16066ETL+ Maxim Integrated Products, MAX16066ETL+ Datasheet - Page 52

no-image

MAX16066ETL+

Manufacturer Part Number
MAX16066ETL+
Description
IC SYSTEM MANAGER 8CH 40-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16066ETL+

Applications
Power Supply Monitor, Sequencer
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN Exposed Pad, 40-HVQFN, 40-SQFN, 40-DHVQFN
Number Of Voltages Monitored
8
Undervoltage Threshold
2.7 V
Manual Reset
Resettable
Watchdog
Yes
Battery Backup Switching
No
Power-up Reset Delay (typ)
200 us
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Supply Current (typ)
10 mA
Maximum Power Dissipation
2105 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Chip Enable Signals
No
Internal Hysteresis
Yes
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Figure
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
U Consider using an external FP to control the EN inputs
U For a large number of voltage rails, the MAX16065/
A FP may control power supplies manually without
involving the sequencing slot system by controlling
EN_OUT_s configured as GPIO_. The output of a power
supply controlled this way can be monitored using a
MON_ input configured as “Monitoring Only(Primary
52
slot on different devices will not come up in the desired
order even if the sequence delays are identical.
or the software enable bits of cascaded devices,
monitoring the RESET outputs as a power-good signal.
MAX16066s can be cascaded hierarchically by using
one master device’s EN_OUT_s to control the EN
inputs of several slave devices.
_____________________________________________________________________________________
19. Graphical User Interface Screenshot
Controlling Power Supplies Without
Using the Sequencer
Sequence)” or “Monitoring Only(Secondary Sequence)”
(see the Monitoring Inputs while Sequencing section). To
monitor the supply for critical faults, the FP will need to
manually set the critical fault enable bit in r6Eh to r72h
after turning on the EN_OUT_, and manually clear the
critical fault enable bit before turning off the EN_OUT_.
The MAX16065/MAX16066 can monitor up to seven
currents using the dedicated current-sense amplifier as
well as up to six pairs of inputs configured in differential
mode. The accuracy of the differential pairs is limited by
the voltage range and the 10-bit conversions. Each input
pair uses an odd-numbered MON_ input in combination
with an even-numbered MON_ input to monitor both the
voltage from the odd-numbered MON_ to ground and
the voltage difference between the two MON_ inputs.
Monitoring Current Using the
Differential Inputs