MAX16066ETL+ Maxim Integrated Products, MAX16066ETL+ Datasheet - Page 41

no-image

MAX16066ETL+

Manufacturer Part Number
MAX16066ETL+
Description
IC SYSTEM MANAGER 8CH 40-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16066ETL+

Applications
Power Supply Monitor, Sequencer
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN Exposed Pad, 40-HVQFN, 40-SQFN, 40-DHVQFN
Number Of Voltages Monitored
8
Undervoltage Threshold
2.7 V
Manual Reset
Resettable
Watchdog
Yes
Battery Backup Switching
No
Power-up Reset Delay (typ)
200 us
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Supply Current (typ)
10 mA
Maximum Power Dissipation
2105 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Chip Enable Signals
No
Internal Hysteresis
Yes
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Table
Table
Table
R = Read/Write select bit.
CRC-8 error check byte is added in the data string dur-
ing each read and/or write sequence. Enable PEC by
writing a ‘1’ to r8Bh[7].
The CRC-8 byte is calculated using the polynomial
The PEC calculation includes all bytes in the transmis-
sion, including address, command, and data. The PEC
calculation does not include ACK, NACK, START, STOP,
or REPEATED START.
The MAX16065/MAX16066 use eight command codes
for block read, block write, and other commands. See
Table 28 for a list of command codes.
To initiate a software reboot, send A7h using the send byte
format. A software-initiated reboot is functionally the same
12-Channel/8-Channel, Flash-Configurable System
COMMAND
REGISTER
ADDRESS
CODE
ACh
A5h
A6h
A7h
A8h
A9h
AAh
ABh
26. SMBus Settings Register
27. Setting the SMBus Slave Address
28. Command codes
8Bh
Managers with Nonvolatile Fault Registers
______________________________________________________________________________________
C = X
Block write
Block read
Reboot flash in register file
Trigger emergency save to flash
Flash page access ON
Flash page access OFF
User flash access ON (must be in flash page already)
User flash access OFF (return to flash page)
FLASH ADDRESS
8
+ X
SDA
SCL
A0
0
1
2
28Bh
+ X + 1
Command Codes
SLAVE ADDRESSES
BIT RANGE
[6:0]
[7]
as a hardware-initiated power-on reset. During boot-up,
flash configuration data in the range of 230h to 28Ch is
copied to r30h to r8Ch registers in the default page.
Send command code A8h to trigger a fault store to flash.
Configure the Critical Fault Log Control register (r6Dh) to
store ADC conversion results and/or fault flags.
While in the flash page, send command code A9h to
access the flash page (addresses from 200h to 28Dh).
Once command code A9h has been sent, all addresses
are recognized as flash addresses only. Send command
code AAh to return to the default page (addresses from
000h to 08Dh). Send command code ABh to access the
user flash-page (addresses from 300h to 39Fh and 3B0h
to 3FFh), and send command code ACh to return to the
flash page.
ACTION
SMBus Slave Address Register. Set to 00h to use A0
pin address setting.
1 = Enable PEC (packet error check).
SLAVE ADDRESS
1010 000R
1010 001R
1010 010R
1010 011R
DESCRIPTION
41