TMP05AKSZ-500RL7 Analog Devices Inc, TMP05AKSZ-500RL7 Datasheet - Page 21

IC PWM TEMP SNSR CMOS/TTL SC70-5

TMP05AKSZ-500RL7

Manufacturer Part Number
TMP05AKSZ-500RL7
Description
IC PWM TEMP SNSR CMOS/TTL SC70-5
Manufacturer
Analog Devices Inc
Datasheet

Specifications of TMP05AKSZ-500RL7

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Averaging Control
Sensor Type
Internal
Sensing Temperature
-40°C ~ 150°C
Output Type
CMOS/TTL
Output Alarm
No
Output Fan
No
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
SC-70-5, SC-88A, SOT-323-5, SOT-353, 5-TSSOP
Ic Output Type
Digital
Sensing Accuracy Range
± 2°C
Supply Current
425µA
Supply Voltage Range
3V To 5.5V
Resolution (bits)
12bit
Sensor Case Style
SC-70
No. Of Pins
5
Temperature Sensor Function
Temp Sensor
Package Type
SC-70
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (max)
5.5V
Accuracy
± 0.5
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
TMP05AKSZ-500RL7TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP05AKSZ-500RL7
Manufacturer:
Analog Devices Inc
Quantity:
1 930
TMP05 Program Code Example 1
//=============================================================================================
// Description : This program reads the temperature from 2 daisy-chained TMP05 parts.
//
// This code runs on any standard 8052 part running at 11.0592MHz.
// If an alternative core frequency is used, the only change required is an
// adjustment of the baud rate timings.
//
// P3.2 = Daisy-chain output connected to INT0.
// P3.7 = Conversion control.
// Timer0 is used in gate mode to measure the high time.
// Timer1 is triggered on a high-to-low transition of INT0 and is used to measure
// the low time.
//=============================================================================================
IS TEMPSEGMENT
RESET TIMER 0
START TIMER 1
TEMP_HIGH0
CALCULATE
TO ZERO
= 1
YE S
NO
NO
COPY TIMER 1 VALUES
CHECK IF TIMER 1
IS TEMPSEGMENT
ENTER INTERRUPT
INTO A REGISTER
RESET TIMER 0
USING TIMER 1
USING TIMER 0
RESET TIMER 1
TEMP_HIGH1
TEMP_LOW0
CALCULATE
CALCULATE
IS RUNNING
TO ZERO
VALUES
VALUES
ROUTINE
Figure 36. ADuC812 Interrupt Routine Flowchart
= 2
YES
YES
Rev. B | Page 21 of 28
NO
IS TEMPSEGMENT
USING TIMER 0
TEMP_HIGH2
TEMP_LOW1
CALCULATE
CALCULATE
VALUES
= 3
YE S
NO
EXIT INTERRUPT
TEMPSEGMENT
INCREMENT
ROUTINE
TMP05/TMP06

Related parts for TMP05AKSZ-500RL7