ADM1033ARQZ-REEL7 ON Semiconductor, ADM1033ARQZ-REEL7 Datasheet - Page 30

no-image

ADM1033ARQZ-REEL7

Manufacturer Part Number
ADM1033ARQZ-REEL7
Description
IC THERM/FAN SPEED CTRLR 16-QSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1033ARQZ-REEL7

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 41. Register 0x09, Mask Register 2, Power−On Default 0x18, Lock = N, S/W Reset = Y
Table 42. Register 0x0A, Mask Register 3, Power−On Default 0x00, Lock = N, S/W Reset = Y
Table 43. Register 0x0B, Local High Limit, Power−On Default 0x8B, Lock = N, S/W Reset = N
Table 44. Register 0x0C, Local Low Limit, Power−On Default 0x54, Lock = N, S/W Reset = N
Table 45. Register 0x0D, Local THERM Limit, Power−On Default 0x95, Lock = Y, S/W Reset = Y
Table 46. Register 0x0E, Remote 1 High Limit, Power−On Default 0x8B, Lock = N, S/W Reset = N
Table 47. Register 0x0F, Remote 1 Low Limit, Power−On Default 0x54, Lock = N, S/W Reset = N
<7:5>
<1:0>
<7:0>
<7:0>
<7:0>
<7:0>
<7:0>
Bit
Bit
Bit
Bit
Bit
Bit
Bit
4
3
2
7
6
4
3
2
1
0
Unused
THERM %
THERM Assert
THERM_State
Unused
Fan 1 Stalled
Fan Alarm Speed
Reserved
Reserved
Reserved
Reserved
Reserved
Local High Limit
Local Low Limit
Local THERM Limit
Remote 1 High Limit
Remote 1 Low Limit
Name
Name
Name
Name
Name
Name
Name
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
Unused.
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 1.
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 0.
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 0. This bit has no effect in
ALERT comparator mode, because the corresponding status bit does not generate an
ALERT in that mode.
Unused.
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 0.
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
When the local temperature exceeds this temperature, the corresponding interrupt
status bit is set.
When the local temperature falls below this temperature, the corresponding interrupt
status bit is set.
When the local temperature exceeds this temperature, the corresponding status bit is
set and the THERM output is activated.
When the Remote 1 temperature exceeds this temperature, the corresponding interrupt
status bit is set.
When the Remote 1 temperature falls below this temperature, the corresponding
interrupt status bit is set.
http://onsemi.com
30
Description
Description
Description
Description
Description
Description
Description

Related parts for ADM1033ARQZ-REEL7