AFBR-59M5LZ Avago Technologies US Inc., AFBR-59M5LZ Datasheet - Page 16

TXRX OPT 850NM SFF 2X6

AFBR-59M5LZ

Manufacturer Part Number
AFBR-59M5LZ
Description
TXRX OPT 850NM SFF 2X6
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of AFBR-59M5LZ

Applications
Ethernet
Data Rate
2.215Gbd
Wavelength
850nm
Voltage - Supply
2.97 V ~ 3.63 V
Connector Type
LC Duplex
Mounting Type
Through Hole
Data Rate Max
2.125Gbps
Supply Voltage
3.3V
Wavelength Typ
850nm
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 14. EEPROM Serial ID Memory Contents – Soft Commands (Address A2h, Byte 110)
Notes:
1. The response time for soft commands of the AFBR-59M5LZ is 100msec as specified by the MSA SFF-8472
2. Bit 6 is logic OR’d with the SFF TX_DISABLE input pin 8 either asserted will disable the SFF transmitter.
3. AFBR-59M5LZ meets the MSA SFF-8472 data ready timing of 1000 msec.
Table 15. EEPROM Serial ID Memory Contents – Alarms and Warnings (Address A2h, Bytes 112, 113, 116, 117)
16
Bit #
7
6
5
4
3
2
1
0
Byte
112
113
116
117
Status/Control Name
TX_ DISABLE State
Soft TX_ DISABLE
reserved
reserved
reserved
TX_FAULT State
Signal Detect State
Data Ready (Bar)
Bit
7
6
5
4
3
2
1
0
7
6
0-5
7
6
5
4
3
2
1
0
7
6
0-5
Flag Bit Name
Temp High Alarm
Temp Low Alarm
V
V
Tx Bias High Alarm
Tx Bias Low Alarm
Tx Power High Alarm
Tx Power Low Alarm
Rx Power High Alarm
Rx Power Low Alarm
reserved
Temp High Warning
Temp Low Warning
V
V
Tx Bias High Warning
Tx Bias Low Warning
Tx Power High Warning
Tx Power Low Warning
Rx Power High Warning
Rx Power Low Warning
reserved
CC
CC
CC
CC
High Alarm
Low Alarm
High Warning
Low Warning
Description
Digital state of SFF TX_ DISABLE Input Pin (1 = TX_DISABLE asserted)
Read/write bit for changing digital state of SFF TX_DISABLE function
Digital state of the laser fault function (1 = Laser Fault Detected)
Digital state of the SFF Sig_Det Output Pin (1 = Signal Detect asserted)
Indicates transceiver is powered and real time sense data is ready. (0 = Ready)
Description
Set when transceiver internal temperature exceeds high alarm threshold.
Set when transceiver internal temperature exceeds low alarm threshold.
Set when transceiver internal supply voltage exceeds high alarm threshold.
Set when transceiver internal supply voltage exceeds low alarm threshold.
Set when transceiver laser bias current exceeds high alarm threshold.
Set when transceiver laser bias current exceeds low alarm threshold.
Set when transmitted average optical power exceeds high alarm threshold.
Set when transmitted average optical power exceeds low alarm threshold.
Set when received average optical power exceeds high alarm threshold.
Set when received average optical power exceeds low alarm threshold.
Set when transceiver internal temperature exceeds high warning threshold.
Set when transceiver internal temperature exceeds low warning threshold.
Set when transceiver internal supply voltage exceeds high warning threshold.
Set when transceiver internal supply voltage exceeds low warning threshold.
Set when transceiver laser bias current exceeds high warning threshold.
Set when transceiver laser bias current exceeds low warning threshold.
Set when transmitted average optical power exceeds high warning threshold.
Set when transmitted average optical power exceeds low warning threshold.
Set when received average optical power exceeds high warning threshold.
Set when received average optical power exceeds low warning threshold.
1
Notes
1
1, 2
1
1
1