ZUP10-20/U TDK Corporation, ZUP10-20/U Datasheet - Page 28

PWR SUP BENCH PROG 0-10V 200W

ZUP10-20/U

Manufacturer Part Number
ZUP10-20/U
Description
PWR SUP BENCH PROG 0-10V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP10-20/U

Number Of Outputs
1
Efficiency
77%
Voltage - Output
0 ~ 10V
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 10 VDC @ 20A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
20A
Input Voltage
85 to 265V
Output Power (max)
200W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Accuracy
0.02% + 8 mV
Brand/series
ZUP
Current, Output
20 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
10 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1668
Q1074270
ZUP10-20/U
ZUP1020/U
4.1
This chapter describes the operating modes, controls and indicators of the ZUP power supply series.
Details of local operation via the front panel and various modes of operation are described in this
chapter, including remote analog control via the rear panel. For computer control via the Serial port
(RS232 or RS485), refer to chapter 5.
4.2 CONTROLS AND INDICATORS
4.2.1 Front panel
Fig. 4-1: Front panel controls and indicators
CHAPTER 4 OPERATING INSTRUCTIONS
13
12
11
1
2
INTRODUCTION
3
10
4
9
5
7
8
6

Related parts for ZUP10-20/U