HSC-ADC-EVALCZ Analog Devices Inc, HSC-ADC-EVALCZ Datasheet - Page 30

KIT EVAL ADC FIFO HI SPEED

HSC-ADC-EVALCZ

Manufacturer Part Number
HSC-ADC-EVALCZ
Description
KIT EVAL ADC FIFO HI SPEED
Manufacturer
Analog Devices Inc

Specifications of HSC-ADC-EVALCZ

Design Resources
EVALC PC Board Gerber File
Accessory Type
ADC Interface Board
Silicon Manufacturer
Analog Devices
Application Sub Type
ADC
Kit Application Type
Data Converter
Features
Buffer Memory Board For Capturing Digital Data, USB Port Interface, Windows 98, Windows 2000
Kit Contents
ADC Analyzer, Buffer Memory Board
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Single ADC Version
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HSC-ADC-EVALCZ
Manufacturer:
Analog Devices Inc
Quantity:
135
AN-905
COMPONENTS RESULTS
DATA GRID
Data Grid displays data in a tabular format. This works on all
data sets both in time and frequency domains. It also works
with most other data types.
Copy data from the Data Grid and paste it into other applica­
tions such as Excel®. Highlight the data, copy the data to the
clipboard, and paste into the new application. To select the
entire grid, select the first item in the list and use Ctrl + Shift +
End to select all items. Then copy data to the clipboard.
GRAPH
Graph displays plot data from all types of processes. It allows
multiple inputs on the same plot by overlaying data sets of
different colors. The graph allows a second plot option when
there is more than one data type routed to the component.
Each plot has an LED indicator at the top left that shows the
selected state of the plot. If you would like to select the plot for
zooming, click the frame and make sure the LED is green. If the
plot is unselected, the LED is red.
If two plots are used, zoom in on or restore both. When zooming
using the box drawing methods, the plots zoom proportionally.
Figure 78. Data Grid Form
Figure 79. Graph
Rev. 0 | Page 30 of 40
To zoom using the box drawing methods, position the cursor
on the upper left of the desired region, drag to the lower right
of the region.
Graph Toolbar
There are several tool buttons on the graph component to
extend the graph functionality.
Graph Settings
To access Graph Settings click Settings.
General
Use the General tab to set parameters that affect the behavior of
the component.
Float Form removes the user interface from the compo­
nent, and places it on a floating form.
Settings shows the Settings form.
Show Analysis Results toggles the visible state of the results
panel on the left side of the component. This panel is
useful when looking at analysis results and plot data.
Toggle Additional Plot toggles the visible state of a second
plot. This is useful when looking at more than one type of
data (for example, FFT and time data).
Save Data As allows you to choose from the currently
plotted analysis data and save to a comma-separated values
(.csv) file.
Append Results File(s) allows you to append analysis
results only to files selected in the Graph Settings. See
the Graph Settings section for more information.
Zoom – Restore restores the zoom-state of the selected
plot(s) to the default coordinates for the current data type
on the plot(s).
Zoom – Coordinates prompts the user for coordinates and
sets the bounds of the selected plots(s) to those coordinates.
Zoom – Box sets the current zoom mode to box. Drawing
a box causes the plot to zoom to the coordinates of the box
drawn on the plot. If the other plot is selected, it zooms
proportionally.
Zoom – Horizontal sets the current zoom mode to
horizontal. Drawing a box causes the plot to zoom to the
horizontal coordinates of the box drawn on the plot. If the
other plot is selected, it zooms proportionally.
Zoom – Vertical sets the current zoom mode to vertical.
Drawing a box causes the plot to zoom to the vertical
coordinates of the box drawn on the plot. If the other plot
is selected, it zooms proportionally.