STEVAL-ILB001V2 STMicroelectronics, STEVAL-ILB001V2 Datasheet - Page 23

BOARD EVAL BIPO SOLUTION FOR PFC

STEVAL-ILB001V2

Manufacturer Part Number
STEVAL-ILB001V2
Description
BOARD EVAL BIPO SOLUTION FOR PFC
Manufacturer
STMicroelectronics
Datasheets

Specifications of STEVAL-ILB001V2

Mfg Application Notes
HF Ballast AppNote
Design Resources
STEVAL-ILB001V2 Gerber Files STEVAL-ILB001V2 Schematic STEVAL-ILB001V2 Bill of Materials
Main Purpose
Lighting, Ballast Control
Embedded
No
Utilized Ic / Part
L6569
Primary Attributes
40W HF Ballast
Secondary Attributes
Discontinuous Mode Boost Converter
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6409
STEVAL-ILB001V2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-ILB001V2
Manufacturer:
ST
0
AN2349
5
5.1
5.2
T Transformer and L
220V design
The transformer T has to be choosen as following:
1.
2.
3.
4.
The Boost inductor L1 has to be choosen as following:
1.
2.
3.
120V design
The transformer T has to be choosen as following:
1.
2.
3.
4.
The Boost inductor L1 has to be choosen as following:
1.
2.
3.
The core type is N87-EFD25/13/9 by Epcos
The wire gauge used to wind the transformer is 0.28 mm
The number of primary winding is 150 turns, the air gap lenght has been chosen in
order to obtain a saturation current of about 1.6A and an inductance value of 2.2mH ±
2.5%
The number of secondary winding is 2 turns for each of the two secondaries
The core type is N27-E20/6 (EF20) by Epcos
The number of primary winding is 150 turns, the air gap length has been chosen in
order to obtain a saturation current of about 1.7A and an inductance value of 1.8mH ±
2.5%
The wire gauge to wind the transformer is 0.22 mm
The core type is N87-EFD25/13/9 by Epcos
The wire gauge used to wind the transformer is 0.28 mm
The number of primary winding is 150 turns, the air gap lenght has been chosen in
order to obtain a saturation current of about 1.7A and an inductance value of 2.1mH ±
2.5%
The number of secondary winding is 3 turns in the PFC stage and 2 turns in the
converter stage
The core type is N27-E20/6 (EF20) by Epcos
The number of primary winding is 150 turns, the air gap lenght has been chosen in
order to obtain a saturation current of about 1.7A and an inductance value of 1.5mH ±
2.5%
The wire gauge to wind the transformer is 0.22 mm
1
inductor specifications
T Transformer and L1 inductor specifications
23/30

Related parts for STEVAL-ILB001V2