DAK-85 Power Integrations, DAK-85 Datasheet - Page 6

DESIGN ACCELERATOR KIT LP SWITCH

DAK-85

Manufacturer Part Number
DAK-85
Description
DESIGN ACCELERATOR KIT LP SWITCH
Manufacturer
Power Integrations
Series
LinkSwitch®-LPr
Datasheets

Specifications of DAK-85

Main Purpose
AC/DC, Primary Side
Outputs And Type
1, Isolated
Power - Output
2W
Voltage - Output
6V
Current - Output
330mA
Voltage - Input
90 ~ 265VAC
Regulator Topology
Flyback
Frequency - Switching
66kHz
Board Type
Bare (Unpopulated) and Fully Populated
Utilized Ic / Part
LNK562, LNK563, LNK564
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
596-1104

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DAK-85
Manufacturer:
Power Integrations
Quantity:
135
2 Power Supply Specification
Input
Voltage
Frequency
No-load Input Power
Output
Output Voltage
Output Ripple Voltage
Output Current
Total Output Power
Continuous Output Power
Efficiency
Environmental
Conducted EMI
Safety
Surge
External Ambient Temperature
Description
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
10
9
8
7
6
5
4
3
2
1
0
0
Figure 2 – Low Cost Charger Output Envelope Specification.
0.1
0.2
V
RIPPLE_TOTAL
Symbol
V
V
V
V
0.3
V
T
RIPPLE1
RIPPLE2
RIPPLE3
RIPPLE4
I
P
f
OUT1
V
LINE
OUT1
AMB
OUT
η
IN
0.4
Output Current (A)
Min
5.5
0.3
Designed to meet IEC950, UL1950
90
47
57
0.5
-5
Meets CISPR22B / EN55022B
Meets IEC61000-4-5 Class 3
0.33
Typ
0.6
200
200
200
400
800
2.0
6
Class II
0.7
Max
0.15
265
63
45
0.8
mVpp
mVpp
mVpp
mVpp
mVpp
Units
VAC
Hz
o
W
W
%
V
A
C
0.9
Ave. 25/50/75/100% load, 25
1
Measured at 115/230 VAC
90 VAC, max. power point
Free convection, sea level
90VAC max. power point
200 kHz – 400 kHz
20 kHz – 200 kHz
2 Wire – no P.E.
1.1
230 VAC, 25
20 Hz – 20 kHz
Total combined
>6 dB margin
Comment
0 – 20 Hz
Page 6 of 32
1.2
o
C
o
C

Related parts for DAK-85