As touch screen controllers and drivers become more sophisticated, it
is now more important than ever that your system is setup properly.
Please review the following steps to ensure that your system is ready.
Bergquist 5-Wire controllers are universal by design.This means the
controller may be configured for a number of communication and
power settings. Please check your 5-Wire controller board to ensure that
these user-configurable settings are set correctly for your application.
You may find the users guide for the Bergquist 5-Wire controller
board at: www.bergquistcompany.com/to_electrical_info.cfm.
Select the “Boards” tab then proceed to the 5-Wire controller
Make sure that you do not have another manufacturer’s touch screen
controller driver installed on your system. Many touch screen
manufacturers’ uninstall programs do not completely remove all
INSTALL THE DRIVER:
1. Connect the 5-Wire controller to your computer (see 5-Wire Controller
2. Turn on your computer.
3. Run the Setup.exe program provided with the Bergquist driver’s disk or from the
4. The Welcome to Bergquist installation screen will appear (see Figure 1). Read the
LICENSE AGREEMENT:
In order to proceed with the installation process, you must agree to the Bergquist
license agreement (see Figure 2). Bergquist drivers are available at no charge to
Bergquist touch screen controller board or chip customers only. Any unlawful use
of Bergquist drivers is in strict violation of the United States and international
copyright laws. Please contact Bergquist if you have any questions regarding the
license agreement.
5. Click “I accept all of the terms of the above License Agreement. ”
6. Click “Next. ”
Before You Begin — Driver Installation & Setup
If yours is a USB application, Microsoft Windows
Wait until Windows completes this process before proceeding.
directory that the drivers are copied to. Note: If Windows asks if you want to allow
an unsigned driver to be installed, click “Accept, ” and continue.
information on the screen, then click “Next. ”
User’s Guide).
®
will load a temporary driver.
For Additional Info 1-800-79-TOUCH
Installation Instructions & User Guide
product.
UNIVERSAL WINDOWS
www.bergquistcompany.com
components of their drivers. Note: Before loading the new driver,
you must first uninstall your current touch screen driver with the latest
uninstall utility located in the “Common” directory of the driver files.
Bergquist drivers use your display driver software settings to accurately
configure various touch screen driver setup files. Make sure that your
display and your display driver cards are installed properly before
installing any 5-Wire touch screen controller driver. If your display(s) are
not configured and are working properly prior to loading the Bergquist
controller drivers, the 5-Wire controllers will not function properly.
Now that you have double-checked your system settings and have
verified that your system is working properly, proceed with the 5-Wire
controller driver installation procedure.
®
TOUCH SCREEN DRIVER
Figure 1
Figure 2

Related parts for 400293

400293 Summary of contents

Page 1

... Note: If Windows asks if you want to allow an unsigned driver to be installed, click “Accept, ” and continue. 4. The Welcome to Bergquist installation screen will appear (see Figure 1). Read the information on the screen, then click “Next. ” LICENSE AGREEMENT: In order to proceed with the installation process, you must agree to the Bergquist license agreement (see Figure 2) ...

Page 2

SELECT 5-WIRE CONTROLLER TYPE: Refer to Figure 3.The “ Bit Controller” is automatically selected for you the “Controller Interface” field, select “Serial (RS-232), ” “USB” or “PS/2, ” depending on your application. If you select the ...

Page 3

... Refer to Figure 7. 14. Run the Bergquist 5-Wire Control Panel as follows: Start Menu > Programs > Bergquist Touch Screen Control Panel If you do not interact with the Control Panel within 10 seconds, the Bergquist calibration program will be launched (see “Configure Calibration Options”). CONFIGURING YOUR 5-WIRE CONTROLLER(S) FOR MULTI-MONITOR USE: Refer to Figure 8 ...

Page 4

CONFIGURE CALIBRATION OPTIONS: 1. Click the “Calibration” tab. The Calibration screen will appear (see Figure 9). 2. Click “Configure. ” The Calibration Options screen will appear (see Figure 10). 3. Select the calibration type and offset options: 3-Point Calibration - ...

Page 5

In-Process Calibration Test (continued) 2. Select “Accept” to apply and record your calibration data. Select “Cancel” to return to the Calibration tab. 3. Once you return to the Calibration tab, click “OK” or “Apply” to save your settings. If you ...

Page 6

... Select “Bergquist 5-Wire-xxxxx” from the list Click “Remove, ” Run the uninstall program file tsun10.exe.This file is located in the “Common” directory of the files you received from The Bergquist Company. 4) Read the message box, then accept. 5) Reboot the system when prompted to do so. ...

Page 7

... Driver Not Installed: A USB controller will operate in a default mode when first plugged in. However, it will not be calibrated.You must install the Bergquist 5-Wire driver to calibrate the touch screen as well as enable all other Bergquist 5-Wire features. ...

Page 8

... Phone: 800-347-4572 Fax: 31-35-5380295 Fax: 952-835-0430 © 2007 The Bergquist Company, Inc. All rights reserved. Reproduction of the contents of this copyrighted material in whole or in part, by any means, mechanically or electronic, for any purpose, without the written permission of The Bergquist Company, Inc. is prohibited. Microsoft ® ...