AS5040 DB V2 austriamicrosystems, AS5040 DB V2 Datasheet - Page 26

BOARD DEMO AS5040

AS5040 DB V2

Manufacturer Part Number
AS5040 DB V2
Description
BOARD DEMO AS5040
Manufacturer
austriamicrosystems
Datasheets

Specifications of AS5040 DB V2

Sensor Type
Magnetic, Rotary Position
Sensing Range
360°
Interface
USB
Voltage - Supply
5V USB or 9V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
AS5040
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Sensitivity
-
AS5040
Data Sheet
18 Angular Output Tolerances
Accuracy
Accuracy is defined as the error between measured angle and actual angle. It is influenced by several factors:
As a sum of all these errors, the accuracy with centered magnet = (Err
degrees @ 25°C (see Figure 25).
Misalignment of the magnet further reduces the accuracy. Figure 24 shows an example of a 3D-graph displaying non-
linearity over XY-misalignment. The center of the square XY-area corresponds to a centered magnet (see dot in the
center of the graph). The X- and Y- axis extends to a misalignment of ±1mm in both directions. The total misalignment
area of the graph covers a square of 2x2 mm (79x79mil) with a step size of 100µm.
For each misalignment step, the measurement as shown in Figure 25 is repeated and the accuracy
(Err
Figure 24: Example of Linearity Error over XY Misalignment
The maximum non-linearity error on this example is better than ±1 degree (inner circle) over a misalignment radius of
~0.7mm. For volume production, the placement tolerance of the IC within the package (±0.235mm) must also be
taken into account.
The total nonlinearity error over process tolerances, temperature and a misalignment circle radius of 0.25mm is
specified better than ±1.4 degrees.
The magnet used for this measurement was a cylindrical NdFeB (Bomatec® BMN-35H) magnet with 6mm diameter
and 2.5mm in height.
www.austriamicrosystems.com
max
– Err
the non-linearity of the analog-digital converters,
internal gain and mismatch errors,
non-linearity due to misalignment of the magnet
min
)/2 (e.g. 0.25° in Figure 25) is entered as the Z-axis in the 3D-graph.
6
°
5
4
3
2
1
0
Linearity Error over XY-misalignment [°]
y
Revision 2.10
-1000
-800
-600
-400
max
-200
0
200
400
– Err
600
x
800
1000
min
)/2 is specified as better than ±0.5
26 - 33