C8051F120DK Silicon Laboratories Inc, C8051F120DK Datasheet - Page 187

DEVKIT-F120/21/22/23/24/25/26/27

C8051F120DK

Manufacturer Part Number
C8051F120DK
Description
DEVKIT-F120/21/22/23/24/25/26/27
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheet

Specifications of C8051F120DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F12x and C8051F13x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F120
Silicon Family Name
C8051F12x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F120, 121, 122, 123, 124, 125, 126, 127
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1224

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F120DK
Manufacturer:
SiliconL
Quantity:
4
Part Number:
C8051F120DK
Manufacturer:
*
Quantity:
1
XTLVLD, in crystal mode software should delay at least 1 ms between enabling the external oscillator and
checking XTLVLD. RC and C modes typically require no startup time. The PLL also requires time to lock
onto the desired frequency, and the PLL Lock Flag (PLLLCK in register PLL0CN) is set to ‘1’ by hardware
once the PLL is locked on the correct frequency.
14.2. External Oscillator Drive Circuit
The external oscillator circuit may drive an external crystal, ceramic resonator, capacitor, or RC network. A
CMOS clock may also provide a clock input. For a crystal or ceramic resonator configuration, the crystal/
resonator must be wired across the XTAL1 and XTAL2 pins as shown in Option 1 of Figure 14.1. In RC,
capacitor, or CMOS clock configuration, the clock source should be wired to the XTAL2 and/or XTAL1
pin(s) as shown in Option 2, 3, or 4 of Figure 14.1. The type of external oscillator must be selected in the
OSCXCN register, and the frequency control bits (XFCN) must be selected appropriately (see SFR Defini-
tion 14.4).
14.3. System Clock Selection
The CLKSL1-0 bits in register CLKSEL select which oscillator source generates the system clock.
CLKSL1-0 must be set to ‘01’ for the system clock to run from the external oscillator; however the external
oscillator may still clock certain peripherals, such as the timers and PCA, when the internal oscillator or the
PLL is selected as the system clock. The system clock may be switched on-the-fly between the internal
and external oscillators or the PLL, so long as the selected oscillator source is enabled and settled. The
internal oscillator requires little start-up time, and may be enabled and selected as the system clock in the
same write to OSCICN. External crystals and ceramic resonators typically require a start-up time before
they are settled and ready for use as the system clock. The Crystal Valid Flag (XTLVLD in register
OSCXCN) is set to ‘1’ by hardware when the external oscillator is settled. To avoid reading a false
Rev. 1.4
C8051F120/1/2/3/4/5/6/7
C8051F130/1/2/3
187

Related parts for C8051F120DK