101-0587 Rabbit Semiconductor, 101-0587 Datasheet - Page 89

KIT DEV RABBITCORE/RCM3400

101-0587

Manufacturer Part Number
101-0587
Description
KIT DEV RABBITCORE/RCM3400
Manufacturer
Rabbit Semiconductor
Series
RabbitCore 3000r
Type
MPU Moduler
Datasheet

Specifications of 101-0587

Rohs Status
RoHS non-compliant
Contents
RabbitCore Module, Dev. Board, AC Adapter, Cable and Dynamic C® CD-Rom
Processor To Be Evaluated
RCM3400
Data Bus Width
8 bit
Interface Type
Ethernet
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
2.8 V to 3.45 V
For Use With/related Products
RCM3400
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
316-1027
B.4.3.3 A/D Converter Calibration
All single-ended inputs are factory-calibrated with actual voltages at a gain code of 0.
Typical values for the other gain codes and for other calibration constants for current and
differential measurements are used to populate the table to allow A/D conversions to be
done “out of the box.” To get the best results form the A/D converter, it is necessary to
calibrate each mode (single-ended, differential, and current) for each of its gains. It is
imperative that you calibrate each of the A/D converter inputs in the same manner as they
are to be used in the application. For example, if you will be performing floating differen-
tial measurements or differential measurements using a common analog ground, then cali-
brate the A/D converter in the corresponding manner. The calibration must be done with
the attenuator reference selection jumper in the desired position (see Figure B-6). If a cali-
bration is performed and the jumper is subsequently moved, the corresponding input(s)
must be recalibrated. The calibration table in software only holds calibration constants
based on mode, channel, and gain. Other factors affecting the calibration must be taken
into account by calibrating using the same mode and gain setup as in the intended use.
Sample programs are provided to illustrate how to read and calibrate the various A/D
inputs for the three operating modes.
These sample programs are found in the
Section 3.2.2 for more information on these sample programs and how to use them.
User’s Manual
Single-Ended, one channel
Single-Ended, all channels
Milli-Amp, one channel
Differential, analog ground
Mode
AD_RDVOLT_ALL.C
AD_RDMA_CH.C
AD_RDDIFF_CH.C
SAMPLES\RCM3400\ADC
Read
AD_CAL_CHAN.C
AD_CAL_ALL.C
AD_CALMA_CH.C
AD_CALDIFF_CH.C
subdirectory. See
Calibrate
83