C8051F064EK Silicon Laboratories Inc, C8051F064EK Datasheet - Page 291

KIT EVAL FOR C8051F064

C8051F064EK

Manufacturer Part Number
C8051F064EK
Description
KIT EVAL FOR C8051F064
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F064EK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F06x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F064
Silicon Family Name
C8051F06x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F064
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1219
Bit7:
Bit6:
Bit5:
Bit4:
Bit3:
Bit2:
Bit1:
Bit0:
R/W
TF1
Bit7
TF1: Timer 1 Overflow Flag.
Set by hardware when Timer 1 overflows. This flag can be cleared by software but is auto-
matically cleared when the CPU vectors to the Timer 1 interrupt service routine.
0: No Timer 1 overflow detected.
1: Timer 1 has overflowed.
TR1: Timer 1 Run Control.
0: Timer 1 disabled.
1: Timer 1 enabled.
TF0: Timer 0 Overflow Flag.
Set by hardware when Timer 0 overflows. This flag can be cleared by software but is auto-
matically cleared when the CPU vectors to the Timer 0 interrupt service routine.
0: No Timer 0 overflow detected.
1: Timer 0 has overflowed.
TR0: Timer 0 Run Control.
0: Timer 0 disabled.
1: Timer 0 enabled.
IE1: External Interrupt 1.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It can be
cleared by software but is automatically cleared when the CPU vectors to the External Inter-
rupt 1 service routine if IT1 = 1. This flag is the inverse of the /INT1 signal.
IT1: Interrupt 1 Type Select.
This bit selects whether the configured /INT1 interrupt will be falling-edge sensitive or
active-low.
0: /INT1 is level triggered, active-low.
1: /INT1 is edge triggered, falling-edge.
IE0: External Interrupt 0.
This flag is set by hardware when an edge/level of type defined by IT0 is detected. It can be
cleared by software but is automatically cleared when the CPU vectors to the External Inter-
rupt 0 service routine if IT0 = 1. This flag is the inverse of the /INT0 signal.
IT0: Interrupt 0 Type Select.
This bit selects whether the configured /INT0 interrupt will be falling-edge sensitive or
active-low.
0: /INT0 is level triggered, active logic-low.
1: /INT0 is edge triggered, falling-edge.
TR1
R/W
Bit6
TF0
R/W
Bit5
Figure 24.4. TCON: Timer Control Register
TR0
R/W
Bit4
Rev. 1.2
R/W
IE1
Bit3
C8051F060/1/2/3/4/5/6/7
R/W
IT1
Bit2
R/W
IE0
Bit1
SFR Address:
SFR Page:
R/W
Bit0
IT0
0x88
0
Addressable
Reset Value
00000000
Bit
291