C8051T600DK Silicon Laboratories Inc, C8051T600DK Datasheet - Page 129

KIT DEV FOR C8051T60X MCU'S

C8051T600DK

Manufacturer Part Number
C8051T600DK
Description
KIT DEV FOR C8051T60X MCU'S
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051T600DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051T60x
Interface Type
USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051T600, C8051T601, C8051T602, C8051T603, C8051T604, C8051T605
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1404
ARBLOST
TXMODE
MASTER
ACKRQ
STO
ACK
STA
Bit
SI
Table 23.3. Sources for Hardware Changes to SMB0CN
A START is generated.
START is generated.
SMB0DAT is written before the start of an
SMBus frame.
A START followed by an address byte is
received.
A STOP is detected while addressed as a
slave.
Arbitration is lost due to a detected STOP.
A byte has been received and an ACK
response value is needed (only when
hardware ACK is not enabled).
A repeated START is detected as a
MASTER when STA is low (unwanted
repeated START).
SCL is sensed low while attempting to
generate a STOP or repeated START
condition.
SDA is sensed low while transmitting a 1
(excluding ACK bits).
The incoming ACK value is low 
(ACKNOWLEDGE).
A START has been generated.
Lost arbitration.
A byte has been transmitted and an
ACK/NACK received.
A byte has been received.
A START or repeated START followed by a
slave address + R/W has been received.
A STOP has been received.
Set by Hardware When:
Rev. 1.2
C8051T600/1/2/3/4/5/6
A STOP is generated.
Arbitration is lost.
A START is detected.
Arbitration is lost.
SMB0DAT is not written before the
start of an SMBus frame.
Must be cleared by software.
A pending STOP is generated.
After each ACK cycle.
Each time SI is cleared.
The incoming ACK value is high
(NOT ACKNOWLEDGE).
Must be cleared by software.
Cleared by Hardware When:
129

Related parts for C8051T600DK