ST7MDT20-DVP3 STMicroelectronics, ST7MDT20-DVP3 Datasheet - Page 24

KIT EMULATOR FOR ST72321/324/521

ST7MDT20-DVP3

Manufacturer Part Number
ST7MDT20-DVP3
Description
KIT EMULATOR FOR ST72321/324/521
Manufacturer
STMicroelectronics
Series
ST7-DVP3r
Type
Microcontrollerr

Specifications of ST7MDT20-DVP3

Contents
Main Emulation Board (MEB), Target Emulation Board (TEB), Cables, Power Supply and Documentation
For Use With/related Products
ST72321, ST72324, ST72521
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-4874
In-circuit Communication Configuration
5.2
24/44
During application development, STVD7 software running on your PC provides an
integrated development environment that allows you to debug your application
while it runs on an ST7 that has Debug Modules. To determine if your ST7 has
core debug modules, refer to your ST7xxxx Datasheet. For more information about
in-circuit debugging with STVD7, refer to the STVD7 online help provided with your
software package.
Once you’ve finalized your application, STVP7 software provides a graphical
interface for verifying memory sectors, checking the settings of the option bytes
and programming your ST7. For more information about programming with
STVP7, refer to the STVP7 online help provided with your software package. For
more information about ICC protocol related to your ST7 MCU, you can refer to
your ST7xxxx Datasheet .
ICC connection
To take advantage of ICC, you must integrate an ICC connector into your
application hardware when you start developing your application. To help you
implement ICP and ICD in the development of your application, this section
provides a summary of points you should consider when installing an ICC
connector.
Using the ICC protocol requires that a minimum of 4 and as many as 6 pins of your
ST7 be relayed to the ICC Connector. These connection requirements are
illustrated in
To connect to your application board for ICP
and ICD, you need to install a 10-pin, HE-10
type connector (also called an ICC Connector)
and ensure the appropriate connections to your
ST7. This connector receives the ICC cable
and relays the signals required for ICP and ICD
to your ST7.
Figure 13
, below and summarized in
Figure 3
ST7-DVP3 Emulator User Manual
.

Related parts for ST7MDT20-DVP3