TOOLSTICK542PP Silicon Laboratories Inc, TOOLSTICK542PP Datasheet - Page 182

PLATFORM PROG TOOLSTICK F542

TOOLSTICK542PP

Manufacturer Part Number
TOOLSTICK542PP
Description
PLATFORM PROG TOOLSTICK F542
Manufacturer
Silicon Laboratories Inc
Series
ToolStickr
Type
Microcontroller Programmerr
Datasheets

Specifications of TOOLSTICK542PP

Contents
2 Boards and USB Connecting Cable
Processor To Be Evaluated
C8051F542
Interface Type
USB
Operating Supply Voltage
2.7 V to 3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F542
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1718
C8051F54x
LIN Register Definition 19.6. LIN0ST: LIN0 Status Register
Indirect Address = 0x09
182
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
WAKEUP
ACTIVE
ERROR
ABORT
DTREQ
LININT
DONE
Name
ACTIVE
IDLT
R
7
0
LIN Active Indicator Bit.
0: No transmission activity detected on the LIN bus.
1: Transmission activity detected on the LIN bus.
Bus Idle Timeout Bit. (slave mode only)
0: The bus has not been idle for four seconds.
1: No bus activity has been detected for four seconds, but the bus is not yet in Sleep
mode.
Aborted Transmission Bit. (slave mode only)
0: The current transmission has not been interrupted or stopped. This bit is reset to 0
after receiving a SYNCH BREAK that does not interrupt a pending transmission.
1: New SYNCH BREAK detected before the end of the last transmission or the STOP
bit (LIN0CTRL.7) has been set.
Data Request Bit. (slave mode only)
0: Data identifier has not been received.
1: Data identifier has been received.
Interrupt Request Bit.
0: An interrupt is not pending. This bit is cleared by setting RSTINT (LIN0CTRL.3)
1: There is a pending LIN0 interrupt.
Communication Error Bit.
0: No error has been detected. This bit is cleared by setting RSTERR (LIN0CTRL.2)
1: An error has been detected.
Wakeup Bit.
0: A wakeup signal is not being transmitted and has not been received.
1: A wakeup signal is being transmitted or has been received
Transmission Complete Bit.
0: A transmission is not in progress or has not been started. This bit is cleared at the
start of a transmission.
1: The current transmission is complete.
IDLTOUT
R
6
0
ABORT
R
5
0
DTREQ
Rev. 1.1
R
4
0
Function
LININT
R
3
0
ERROR
R
2
0
WAKEUP
R
1
0
DONE
R
0
0