SF4-DC5V Panasonic Electric Works, SF4-DC5V Datasheet

RELAY SAFETY PC MNT 8PST 6A 5VDC

SF4-DC5V

Manufacturer Part Number
SF4-DC5V
Description
RELAY SAFETY PC MNT 8PST 6A 5VDC
Manufacturer
Panasonic Electric Works
Series
SFr
Datasheet

Specifications of SF4-DC5V

Relay Type
Safety
Contact Form
8PST (4 Form A, 4 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
100mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.75 VDC
Turn Off Voltage (min)
0.75 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
8PST (4 Form A, 4 Form B)
Contact Rating @ Voltage
6A @ 250VAC
Control On Voltage (max)
3.75 VDC
Control Off Voltage (min)
0.75 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1414

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SF4-DC5V
Quantity:
5 400
SF
258
SPECIFICATIONS
Contact
Coil (at 25°C
Remarks
* Specifications will vary with foreign standards certification ratings.
*1
*2
*3
*4
*5
*6
*7
*8
ORDERING INFORMATION
UL/CSA, TÜV, SEV approved type is standard (SF2, SF4)
TÜV approved type is standard (SF3)
Type
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive)
Expected
life (min.
operations)
Nominal operating power
side of contact pairs of each Form A contact and Form B contact
Measurement at same location as " Initial breakdown voltage " section
Detection current: 10mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10 s
Half-wave pulse of sine wave: 6ms
Detection time: 10 s
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
More than 10
2.098 .012
2.098 .012
2: 2 Form A 2 Form B
3: 3 Form A 1 Form B
4: 4 Form A 4 Form B
53.3 0.3
53.3 0.3
Contact arrangement
Ex. SF
Nominal switching
capacity
Max. switching power
Max. switching voltage
Max. carrying current
Mechanical (at 180
cpm) (resistive)
Electrical (at 20 cpm)
5
77°F
2.098 .012
operations when applying the nominal switching capacity to one
53.3 0.3
)
25.0
.984
33 0.3
1.299 .012
2
16.5 0.3
.650 .012
16.5 0.3
.650 .012
mm
25.0
.984
16.5 0.3
.650 .012
DC 12 V
DC 5, 9, 12, 18, 21,
24, 36, 48, 60 V
inch
2 Form A
2 Form B
Coil voltage
POLARISED, MONOSTABLE
SAFETY RELAY with
(mechanical linked) forced
contacts operation
6 A 250 V AC, 6 A 30 V DC
SF2
Gold-flashed silver alloy
30 V DC, 440 V AC
3 10
1,500 VA, 180 W
6 A DC, AC
3 Form A
1 Form B
FEATURES
• Forced operation contacts (2 Form A
2 Form B, 3 Form A 1 Form B)
N.O. and N.C. side contacts are
connected through a card so that one
interacts with the other in movement. In
case of a contact welding, the other
keeps a min. 0.5mm
gap.
• Independent operation contacts
(4 Form A 4 Form B)
Each pair of contacts is free from the
main armature and is independent from
each other. So if a N.O. pair of contacts
are welded, the other 3 N.O. contacts are
not effected (operate properly) That
4
500 mW
*
30 m
1
SF3
10
7
4 Form A
4 Form B
SF4
10
5
.020inch
Characteristics (at 25°C
TYPICAL APPLICATIONS
• Signal
• Escalator
• Elevator
• Medical Instruments
• Railway
• Factory Automation
Max. operating speed
Initial insulation resistance*
Initial break-
down voltage*
Operate time*
(at nominal voltage)
Release time (without diode)*
(at nominal voltage)
Temperature rise
(at nominal voltage)
Vibration
resistance
Conditions for oper-
ation, transport and
storage*
condensing at low
temperature)
Unit weight
(Not freezing and
resistance
Shock
8
contact
4
3
Between con-
tact sets
Between open
contacts
Between con-
tact and coil
Functional*
Destructive*
Functional*
Destructive
Ambient
temp.
Humidity
SF-RELAYS
enables to plan a circuit to detect welding
or go back to the beginning condition.
• Separated chamber structure
(2 Form A 2 Form B, 3 Form A 1 Form B,
4 Form A 4 Form B)
N.O. and N.C. side contacts are put in
each own space surrounded with a card
and a body-separater. That prevents
short circuit between contacts, which is
caused by their springs welding or
damaged.
• UL/CSA, TÜV, SEV approved
(UL/CSA, SEV of SF3 pending)
77°F
2
5
7
5
4
, 50% Relative humidity)
Max. 45 C with nominal coil voltage
SF2
Approx. 17 ms
Approx. 7 ms
–40 C to +70 C
37 g
117.6 m/s
117.6 m/s
180 cpm (at nominal voltage)
at double amplitude of 2 mm
at double amplitude of 2 mm
and at 6 A switching current
Min. 1,000 M
Min. 980 m/s
1.31 oz
Min. 294 m/s
5 to 85% R.H.
SF3
(SF3 pending) (SF3 pending)
2,500 Vrms
2,500 Vrms
2,500 Vrms
2
2
{12 G}, 10 to 55 Hz
{12 G}, 10 to 55 Hz
–40°F to +158°F
at 500 V DC
2
2
Approx. 18 ms
{100 G}
Approx. 6 ms
{30 G}
47 g
SF4
1.66 oz
(SF3 pending)

Related parts for SF4-DC5V

SF4-DC5V Summary of contents

Page 1

... Contact arrangement 2: 2 Form A 2 Form 12, 18, 21 Form A 1 Form B 24, 36, 48 Form A 4 Form B UL/CSA, TÜV, SEV approved type is standard (SF2, SF4) TÜV approved type is standard (SF3) 258 POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation FEATURES • Forced operation contacts (2 Form A 2 Form B, 3 Form A 1 Form B) N ...

Page 2

... SF2-DC18V 18 SF2 SF2-DC21V 21 SF2-DC24V 24 SF2-DC36V 36 SF2-DC48V 48 SF2-DC60V 60 SF3-DC5V 5 SF3-DC9V 9 SF3-DC12V 12 SF3-DC18V 18 SF3 SF3-DC21V 21 SF3-DC24V 24 SF3-DC36V 36 SF3-DC48V 48 SF3-DC60V 60 SF4-DC5V 5 SF4-DC9V 9 SF4-DC12V 12 SF4-DC18V 18 SF4 SF4-DC21V 21 SF4-DC24V 24 SF4-DC36V 36 SF4-DC48V 48 SF4-DC60V 60 DIMENSIONS 1) SF2 25.0 .984 7.62 .300 Pick-up Drop-out Coil voltage, VDC voltage resistance (max.) (min ...

Page 3

... Tolerance: 0.1 ±.004 Schematic (Bottom view board pattern (Bottom view) 18-1.4 DIA. HOLES 2.54 18-.055 DIA. HOLES .100 2.54 .100 Tolerance: 0.1 ±.004 3. Ambient temperature characteristics Tested sample: SF4-DC12V Quantity 100 Drop-out voltage 50 Pick-up voltage -40 - Ambient temperature, C -50 -100 inch ...

Page 4

... SAFETY STRUCTURE OF SF RELAYS This SF relay design ensures that subsequent operations shut down and can automatically return to a safe state when the SF relay suffers overloading and other circuit abnormalities (unforeseen 1. Forced operation method (2a2b, 3a1b, 4a4b types) 2. Independent operation method (4a4b type) 3 ...

Page 5

... SF THE OPERATION OF SF RELAYS (when contacts are welded) SF relays work to maintain a normal operating state even when overloading or short-circuit currents occur also easy to include weld detection circuits and safety circuits in the design to ensure safety even if contacts weld. 1) 2a2b Type Form “b” Contact Weld If the form “ ...

Page 6

Type Form “b” Contact Weld If the form “b” contact (No. 3) welds, the armature becomes non-operational, the contact gaps at the three form “a” contacts are maintained at greater than 0.5 mm .020 No.4 No.1 No.3 No.2 ...

Page 7

SF 3) 4a4b Type Internal Contacts Weld If the internal contacts (nos and 7) weld, the armature becomes non-operational and the contact gaps of each of the four form “a” contacts are maintained at greater than 0.5 ...

Related keywords