SF4-DC5V Panasonic Electric Works, SF4-DC5V Datasheet - Page 7

RELAY SAFETY PC MNT 8PST 6A 5VDC

SF4-DC5V

Manufacturer Part Number
SF4-DC5V
Description
RELAY SAFETY PC MNT 8PST 6A 5VDC
Manufacturer
Panasonic Electric Works
Series
SFr
Datasheet

Specifications of SF4-DC5V

Relay Type
Safety
Contact Form
8PST (4 Form A, 4 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
100mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.75 VDC
Turn Off Voltage (min)
0.75 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
8PST (4 Form A, 4 Form B)
Contact Rating @ Voltage
6A @ 250VAC
Control On Voltage (max)
3.75 VDC
Control Off Voltage (min)
0.75 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1414

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SF4-DC5V
Quantity:
5 400
SF
3) 4a4b Type
If the internal contacts (nos. 2, 3, 6, and 7) weld, the armature becomes non-operational and the contact gaps of each of the four form
“a” contacts are maintained at greater than 0.5 mm
For Cautions for Use, see Relay Technical Information
264
9/1/2000
If the external contacts (nos. 1, 4, 5, and 8) weld, gaps of greater than 0.5 mm
and the coil returns to an non-energized state.
The table below shows the state of the other contacts when the current through the welded form “a” contact is 0 V and the rated volt-
age is applied through the form “b” contact.
No.8
No.7
No.6
No.5
No.8
No.7
No.6
No.5
If external connections are made in series.
Even if one of the contacts welds, because the
other contacts operate independently, the contact
gaps are maintained at greater than 0.5 mm
inch.
No.8
No.6
No.7
No.5
Terminal No. 13–14 5–6 9–10 17–18
External Contacts Weld
Contact No.
Internal Contacts Weld
Contact Operation Table
No.1 No.2 No.3 No.4
Non-energized
Energized
19–20 11–12 7–8 15–16
No.5 No.6 No.7 No.8
No.1
No.2
No.3
No.4
No.1
No.2
No.3
No.4
No.1
No.3
No.2
No.4
.020
Note: Contact gaps are shown at the initial state.
If the contacts change state owing to loading/breaking it is necessary to check the actual loading.
Contact No.
No.8
No.6
No.7
No.5
No.8
No.7
No.6
No.5
terminal
Non-energized (when no. 1 contact is welded)
Welded
Energized (when no. 2 contact is welded)
No.
.020
Contact No.
Non-energized
inch. Reliable isolation is thus ensured.
Energized
1
2
3
4
5
6
7
8
>0.5
>0.5
>0.5
1
>0.5
>0.5
>0.5
>0.5
>0.5
2
Weld
>0.5
>0.5
>0.5
>0.5
>0.5
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
3
State of other contacts
.020 inch
No.1
No.3
>0.5
>0.5
>0.5
No.2
No.4
No.1
No.2
No.3
No.4
4
If the No. 2 contact welds.
Each of the four form "a" contacts (Nos. 1, 3, 5,
and 7) maintains a gap of greater than 0.5 mm
.020
If the No. 1 contact welds.
The adjacent No. 2 contact maintains a gap of
greater than 0.5 mm
tacts, because the coil is not energized, return to
their normal return state; each of form “a” con-
tacts (nos. 3, 5, and 7) maintains a contact gap of
greater than 0.5 mm
“b” contacts (nos. 4, 6, and 8) return to a closed
state.
>0.5
>0.5
>0.5
are maintained between adjacent contacts
5
Contact gap
min 0.5 mm
inch.
>0.5
>0.5
>0.5
>0.5
>0.5
6
.020 inch
>0.5
>0.5
>0.5
>0.5
>0.5
7
.020
.020
>0.5
>0.5
>0.5
8
inch. The other con-
inch; each of the form
>0.5: contact gap
is kept at min. 0.5
mm
Empty cells: either
closed or open
: contact closed
.020 inch

Related parts for SF4-DC5V