1213563-1 Tyco Electronics, 1213563-1 Datasheet - Page 3

no-image

1213563-1

Manufacturer Part Number
1213563-1
Description
TOOL DAHT ADAPTER ASSEMBLY
Manufacturer
Tyco Electronics
Datasheet

Specifications of 1213563-1

Connector Type
DAHT Adaptor
Lead Free Status / RoHS Status
Not applicable / Not applicable
Crimp Handle
-
Crimp Or Cable Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Rev
DAHT Adapter Assembly 1213563-1
DANGER
Crimp Head
(Installed)
3. Using hex wrench supplied with adapter, tighten
cam setscrew, then pull on cam to ensure that it is
firmly attached.
4. Properly align adapter with cam and push
adapter onto power unit so that it passes over the
friction ring on the power unit.
5. Slide locking ring toward adapter until it butts
against the stop ring on the power unit. Then turn
locking ring clockwise to engage threads on the
bottom of the adapter. Tighten locking ring to fully
secure the adapter.
NOTE
6. Rotate the adapter one full turn in each direction
and note that the locking ring rotates with the
adapter.
A
i
Adapter
When adapter is properly installed, the locking
ring should be butted against the stop ring and
threads of the adapter should not be visible. If not
properly installed, check that correct combination
of cam and adapter was used and that they are
aligned properly.
To avoid personal injury, periodically check that
locking ring is tightly securing the adapter.
Tyco Electronics Corporation
Figure 3
Cam
Setscrew
6. MAINTENANCE AND INSPECTION
Tyco Electronics recommends that a maintenance
and inspection program be performed periodically to
ensure dependable and uniform terminations.
6.1. Daily Maintenance
Tyco Electronics recommends that each operator be
responsible for the following steps of daily
maintenance:
DANGER
Adapter
Cam
7. Connect pneumatic tool to an adequate air
supply between 620–690 kPa [90–100 psi]. For
specific information on air line requirements and air
hose installation, refer to Customer Manual
409–5862.
8. Removal is the reverse of installation.
1. Remove dust, moisture, and other contaminants
with a clean, soft brush, or a lint–free cloth. DO
NOT use objects that could damage the adapter.
2. Make sure that all pins, rings, and other
components are in place and secure.
Pneumatic Tool (Power Unit)
To avoid personal injury, ALWAYS disconnect the
main air supply and electrical supply (if
applicable) of the pneumatic tool before
performing maintenance or inspection.
Piston
Rod
Friction
Ring
Stop
Ring
408-4485
Locking
Ring
3
of 5