C200H-OA223 Omron, C200H-OA223 Datasheet - Page 157

no-image

C200H-OA223

Manufacturer Part Number
C200H-OA223
Description
8PT TRIAC
Manufacturer
Omron
Datasheet

Specifications of C200H-OA223

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Programming Instructions
These footnote tables show the actual ranges of all data areas. Bit numbers are provided (except for DM and TC areas); remove the rightmost two digits for word numbers.
Data Areas
ASCII CONVERT
(@)ASC(86)
INTERRUPT CONTROL
(@)INT(89)
00000 to 23515 23600 to 25507
IR
Mnemonic
Name
SR
HR 0000 to 9915
HR
Symbol
ASC(86)
INT(89)
TR 0 to 7
TR
CC
Di
N
D
S
D
AR 0000 to 2715
AR
Converts hexadecimal digits from the
source word (S) into 8-bit ASCII values,
starting at leftmost or rightmost half of the
starting destination word (D). The right-
most digit of Di designates the first source
digit. The next digit to the left gives the
number of digits to be converted. The next
digit specifies the whether the data is to be
transferred to the rightmost (0) or leftmost
(1) half of the first destination word. The
leftmost digit specifies parity:
Controls programmed (scheduled) inter-
rupts and interrupts from Interrupt Input
Units. Each PC can have up to 4 IIUs. N de-
fines the source of the interrupt: 000 to 003
designate the no. of the IIU; 004 desig-
nates a scheduled interrupt. In IIUs, bits 00
to 07 identify the interrupting subroutine,
higher bits are not used. Bit 00 of Unit 0 cor-
responds to interrupt subroutine 00,
through to bit 07 of Unit 3 which corre-
sponds to subroutine 31. CC is the control
code, the meaning of which depends on
the value of N, as follows:
000
001
002
CC
Masks and unmasks in-
terrupt bits for the desig-
nated Unit (N) according
to the data in D. Bits cor-
responding to ON bits in
D are masked, those cor-
responding to OFF bits
are unmasked. Masked
bits are recorded and will
be executed when they
are unmasked (unless
previously cleared).
Clears the masked inter-
rupt bits of the designated
Unit (N) according to the
corresponding ON bits in
D. The subroutines corre-
sponding to bits cleared
in this manner will not be
executed when the bit is
unmasked.
Copies the mask status of
the designated IIU to D.
D
LR 0000 to 6315
S
0: none,
1: even, or
2: odd.
15
N = 000 to 003
LR
Function
08 07
TC 000 to 511
TC
00
The interrupt time
interval is set ac-
cording to the data
in D (00.01 to
99.99 s) The deci-
mal point is not
entered. The in-
terrupt
celled
00.00.
The time to the
first interrupt is set
according to the
data in D (00.01 to
99.99 s) The deci-
mal point is not
entered. The in-
terrupt
celled
00.00.
Copies the time in-
terval data to D.
0 to F
8-bit
data
N = 004
Read/Wr: DM 0000 to DM 0999
Rd only: DM 1000 to DM 1999
if
if
is
is
D
D
can-
can-
is
is
DM
Operand Data Areas
S:
IR
SR
HR
AR
LR
TC
DM
CC:
000 to
002
Appendix E
Di:
IR
HR
LR
TC
DM
#
N:
000 to
004
0000 to 9999
or 0000 to FFFF
#
D:
IR
HR
LR
DM
D:
IR
HR
AR
LR
TC
DM
#
143