C200H-OA223 Omron, C200H-OA223 Datasheet - Page 158

no-image

C200H-OA223

Manufacturer Part Number
C200H-OA223
Description
8PT TRIAC
Manufacturer
Omron
Datasheet

Specifications of C200H-OA223

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Programming Instructions
144
These footnote tables show the actual ranges of all data areas. Bit numbers are provided (except for DM and TC areas); remove the rightmost two digits for word numbers.
Data Areas
NETWORK SEND
(@)SEND(90)
(CPU11)
SUBROUTINE ENTER
(@)SBS(91)
00000 to 23515 23600 to 25507
IR
Mnemonic
Name
SR
HR 0000 to 9915
HR
Symbol
SEND(90)
SBS(91) N
TR 0 to 7
TR
D
C
S
AR 0000 to 2715
AR
Transfers data from n source words (S is
the starting word) to the destination words
(D is the first address) in node N of the spe-
cified network (in a SYSMAC LINK or NET
Link System). The format of the control
words varies depending on the type of sys-
tem. In both types of systems, the first con-
trol word (C) gives the number of words to
be transferred.
For NET Link Systems, in word C+1, bit 14
specifies the system (0 for system 1, and
1 for system 0), and the rightmost 7 bits de-
fine the network number. The left half of
word C+2 specifies the destination port
(00: NSB, 01/02: NSU), and the right half
specifies the destination node number. If
the destination node number is set to 0,
data is transmitted to all nodes.
For SYSMAC LINK Systems, the right half
of C+1 specifies the response monitoring
time (default 00: 2 s, FF: monitoring dis-
abled), the next digit to the left gives the
maximum number of re-transmissions (0
to 15) that the PC will attempt if no re-
sponse signal is received. Bit 13 specifies
whether a response is needed (0) or not
(1), and bit 14 specifies the system number
(0 for system 1, and 1 for system 0). The
right half of C+2 gives the destination node
number. If this is set to 0, the data will be
sent to all nodes.
Calls subroutine N. Moves program opera-
tion to the specified subroutine.
SYSMAC LINK
C
C+1
C+2
C
C+1
C+2
NET Link
LR 0000 to 6315
Source N
S+n–1
S+1
n: no. of words to be transmitted (0 to 1000)
0X00
Destination port no.
n: no. of words to be transmitted, 0 to 1000
0XX0
0000
S
LR
Function
0000
Re-trans-
missions
0000
TC 000 to 511
Destination node N
TC
Network no. (0 to 127)
Destination node no.
(0 to 126)
Response monitor time
(0.1 to 25.4 s)
Destination node no.
(0 to 62)
D+n–1
D+1
D
Read/Wr: DM 0000 to DM 0999
Rd only: DM 1000 to DM 1999
DM
Operand Data Areas
S:
IR
SR
HR
AR
LR
TC
DM
N:
00 to 99
Appendix E
D/C:
IR
HR
AR
LR
TC
DM
0000 to 9999
or 0000 to FFFF
#