S1D15206F00A200 Epson, S1D15206F00A200 Datasheet - Page 148

no-image

S1D15206F00A200

Manufacturer Part Number
S1D15206F00A200
Description
LCD Drivers LCD DRIVER
Manufacturer
Epson
Datasheet

Specifications of S1D15206F00A200

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S1D15206F00A200
Manufacturer:
EPSON/爱普生
Quantity:
20 000
S1D15300 Series
8. COMMAND SETTING (For Refrence)
Instruction Setup Examples
Initial setup
Note: As power is turned on, this IC outputs non-LCD-drive potentials V
• When the built-in power is used immediately after the main power is turned on:
* This duration of 5 ms depends on the panel characteristics as well as capacity of the capacitor concerned.
Notes: *1: Refer to the “Reset Circuit” in the Function Description.
5–24
and V
inserted between the above LCD driving terminals, the display screen can be blacked out momentarily. In order to avoid this trouble,
it is recommended to employ the following powering on procedure.
*2: Refer to the “LCD Bias Set” in the Command Description (11).
*3: Refer to the “ADC Select” in the Command Description (8).
*4: Refer to the “Output State Register Set” in the Command Description (15)
*5: Refer to the “Supply Circuit” in the Function Description and the “Electronic Volume Register Set” in the Command Description
*6: Refer to the “Supply Circuit” in the Function Description and the “Power Control Set” in the Command Description (16).
(17).
1
– V
4
from COM terminal (also used for generating the LCD drive output). If charge remains on the smoothing capacitor being
Function select through the commands (user setup).
Function select through the command (user setup).
Function select through the command (user setup)
Cancel the reset mode (RES terminal = HIGH).
Turn on V
LCD bias set *2
ADC select *3
Common output mode select *4
Electronic volume *5
Power control set *6
Turn on the initial setup mode (Default). *1
Wait until the power supply is stabilized.
DD
Initial setup is complete
RES terminal at LOW.
and V
SS
power while maintaining
EPSON
2
– V
6
Operations ranging from powering on
through the power control set must be
completed within 5 ms.
from SEG terminal (generates output for driving the LCD)
Rev.1.4

Related parts for S1D15206F00A200