S1D15206F00A200 Epson, S1D15206F00A200 Datasheet - Page 243

no-image

S1D15206F00A200

Manufacturer Part Number
S1D15206F00A200
Description
LCD Drivers LCD DRIVER
Manufacturer
Epson
Datasheet

Specifications of S1D15206F00A200

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S1D15206F00A200
Manufacturer:
EPSON/爱普生
Quantity:
20 000
S1D15600/601/602 Series
*3
*2
*1
*1: In the power save sequence, the power save status is
*2 When the COMI pin is not used, it is not necessary to
*3 In the S1D15602, it is not necessary to execute a
*4 The display ON command can be executed any-
7–48
provided after the display all ON command. In the
power save clear sequence, the power save status is
cleared after the display all ON status OFF com-
mand.
eneter the DUTY+1 command and DUTY+1 clear
command.
command to decide an output status.
Power save sequence
Output Status case 6
*DUTY+1 Clear
Display All ON
Display OFF
command
command
command
command
AE(H)
CF(H)
AA(H)
A5(H)
EPSON
*3
*2
*1
*6
*5
*5 When internal power supply startup end command is
*6 The waiting time depends on the Externally-installed
where if it is later than the display all ON status OFF
command.
not executed, current is consumed stationarily. In-
ternal power supply startup end command must
always be used in a pair with internal power supply
ON command.
capacitance C2 (refer to 7-46). After the waiting
time shown in the above Graph 1, the power supply
can be started surely.
Power save clear sequence
Display All ON Status OFF
Power Supply Startup End
Internal Power Supply ON
Reset by RES signal
Output Status Select
(Waiting time)
*DUTY+1
command
command
command
command
Rev. 4.6
C*(H)
AB(H)
25(H)
ED(H)

Related parts for S1D15206F00A200