SAA7118H NXP Semiconductors, SAA7118H Datasheet - Page 66

SAA7118H

Manufacturer Part Number
SAA7118H
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SAA7118H

Adc/dac Resolution
9b
Screening Level
Commercial
Package Type
PQFP
Pin Count
160
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAA7118H
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
SAA7118H/V1
Manufacturer:
PHI-PBF
Quantity:
62
Part Number:
SAA7118H/V1
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
SAA7118H/V1,557
Manufacturer:
Sigma Designs Inc
Quantity:
10 000
Table 20.
[1]
[2]
[3]
Name
SAV
SDID
DC
IDI1
IDI2
D
D
CS
BC
EAV
Fig 41. Sliced data formats on the I port in 8-bit mode
n_m
DC_4
NEP = inverted EP (bit D7); for EP see
EP = even parity (bit D6) of bits D5 to D0.
OP = odd parity (bit D7) of bits D6 to D0.
...
ANC header active for DID (subaddress 5Dh) < 3Eh
Explanation to
FF
Explanation
start of active data; see
sliced data identification: NEP
identifier
double word count: NEP
It should be noted that the number of valid bytes inside the stream can be seen in the BC byte.
internal data identification 1: OP
internal data identification 2: OP
double word number n, byte number m
last double word byte 4; remark: for SAV/EAV framing DC is fixed to 0Bh, missing data bytes are filled up; the fill value is A0h
the check sum byte, the check sum is accumulated from the SAV (respectively DID) byte to the D
number of valid sliced bytes counted from the IDI1 byte
end of active data; see
end of raw VBI line
...
For SAV/EAV mode DC is fixed to 11 double words (byte value 4Bh)
For ANC mode it is: DC =
the chosen text standard
invalid data
00
or
00
00
EAV
00
Figure 41
timing reference code
FF
ANC header
00
Table 21
Table 21
FF
[1]
00
, EP
Table note
1
FF
00
4
[1]
[2]
(C + n), where C = 2 (the two data identification bytes IDI1 and IDI2) and n = number of decoded bytes according to
, EP
[3]
[3]
, DC5 to DC0. DC describes the number of succeeding 32-bit words:
SAV SDID DC
DID SDID DC
, FID (field 1 = 0, field 2 = 1), line number 8 to line number 3 = double word 1 byte 1; see
, line number 2 to line number 0, data type 3 to data type 0 = double word 1 byte 2; see
2.
[2]
, SDID5 to SDID0, freely programmable via I
internal header
internal header
D
IDI1 IDI2 D
IDI1 IDI2 D
1_1
D
1_2
sliced data
sliced data
1_3
1_3
D
D
1_4
1_4
D
...
2_1
D
DC_3
and filling data
...
D
DC_4
2
D
C-bus subaddress 5Eh, D5 to D0, e.g. to be used as source
DC_3
CS
D
BC
DC_4
00
ANC data output is only filled up
to the double word boundary
CS
DC_4
00
BC
byte
timing reference code
FF
...
00
00
EAV
Table 21
Table 21
invalid data
00
00
mhb549
...

Related parts for SAA7118H