CY7C65113-SC Cypress Semiconductor Corp, CY7C65113-SC Datasheet - Page 42

no-image

CY7C65113-SC

Manufacturer Part Number
CY7C65113-SC
Description
IC MCU 8K USB HUB 4 PORT 28-SOIC
Manufacturer
Cypress Semiconductor Corp
Datasheets

Specifications of CY7C65113-SC

Applications
USB Hub/Microcontroller
Core Processor
M8
Program Memory Type
OTP (8 kB)
Controller Series
USB Hub
Ram Size
256 x 8
Interface
I²C, USB
Number Of I /o
11
Voltage - Supply
4 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
28-SOIC (7.5mm Width)
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Package Type
SOIC
Mounting
Surface Mount
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
CY3649 - PROGRAMMER HI-LO USB M8428-1339 - KIT LOW SPEED PERSONALITY BOARD
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
428-1331

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY7C65113-SC
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
A “TX0 Byte” entry in the IN column implies that the SIE transmit a zero length byte packet in response to the IN token received
from the host.
An “Ignore” in any of the columns means that the device will not send any handshake tokens (no ACK) to the host.
An “Accept” in any of the columns means that the device will respond with an ACK to a valid SETUP transaction tot he host.
Comments
Some Mode Bits are automatically changed by the SIE in response to certain USB transactions. For example, if the Mode Bits
[3:0] are set to '1111' which is ACK IN-Status OUT mode as shown in Table 18-1, the SIE will change the endpoint Mode Bits [3:0]
to NAK IN-Status OUT mode (1110) after ACK’ing a valid status stage OUT token. The firmware needs to update the mode for
the SIE to respond appropriately. See Table 18-1 for more details on what modes will be changed by the SIE. A disabled endpoint
will remain disabled until changed by firmware, and all endpoints reset to the disabled mode (0000). Firmware normally enables
the endpoint mode after a SetConfiguration request.
Any SETUP packet to an enabled endpoint with mode set to accept SETUPs will be changed by the SIE to 0001 (NAKing INs
and OUTs). Any mode set to accept a SETUP will send an ACK handshake to a valid SETUP token.
The control endpoint has three status bits for identifying the token type received (SETUP, IN, or OUT), but the endpoint must be
placed in the correct mode to function as such. Non-control endpoints should not be placed into modes that accept SETUPs.
Note that most modes that control transactions involving an ending ACK, are changed by the SIE to a corresponding mode which
NAKs subsequent packets following the ACK. Exceptions are modes 1010 and 1110
.
Table 18-2. Decode table for Table 18-3: “Details of Modes for Differing Traffic Conditions”
The response of the SIE can be summarized as follows:
Document #: 38-08002 Rev. *B
3
Endpoint Mode
encoding
Legend:
1. The SIE will only respond to valid transactions, and will ignore non-valid ones.
2. The SIE will generate an interrupt when a valid transaction is completed or when the FIFO is corrupted. FIFO corruption occurs
3. An incoming Data packet is valid if the count is < Endpoint Size + 2 (includes CRC) and passes all error checking;
4. An IN will be ignored by an OUT configured endpoint and visa versa.
5. The IN and OUT PID status is updated at the end of a transaction.
6. The SETUP PID status is updated at the beginning of the Data packet phase.
during an OUT or SETUP transaction to a valid internal address, that ends with a non-valid CRC.
2
1
0
Received Token
(SETUP/IN/OUT)
Token
TX : transmit
RX : receive
x: don’t care
count
The number of received bytes
available for Control endpoint only
Properties of Incoming
buffer
The quality status of the DMA buffer
UC : unchanged
TX0 :Transmit 0 length packet
Packets
dval
The validity of the received data
DTOG
Data0/1 (bit7 Figure 17-4)
Changes to the Internal Register made by the SIE on receiving an incoming packet
DVAL
Data Valid (bit 6, Figure 17-4)
COUNT
Byte Count (bits 0..5, Figure 17-4)
Setup
from the host
(Bit[7..5], Figure 17-2)
PID Status Bits
In
Out
ACK
Acknowledge phase completed
3
2 1 0 Response
Changed by the SIE
Endpoint Mode bits
CY7C65013
CY7C65113
SIE’s Response
to the Host
Page 42 of 51
Interrupt
Int

Related parts for CY7C65113-SC