MC68306FC16B Freescale Semiconductor, MC68306FC16B Datasheet - Page 89

no-image

MC68306FC16B

Manufacturer Part Number
MC68306FC16B
Description
IC MPU INTEGRATED 132-PQFP
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC68306FC16B

Processor Type
M683xx 32-Bit
Speed
16MHz
Voltage
5V
Mounting Type
Surface Mount
Package / Case
132-MQFP, 132-PQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68306FC16B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306FC16B
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
error, it does allow software diagnosis. Finally, the processor commences instruction
processing at the address in the vector. It is the responsibility of the error handler routine
to clean up the stack and determine where to continue execution.
If a bus error occurs during the exception processing for a bus error, an address error, or
a reset, the processor halts and all processing ceases. This halt simplifies the detection of
a catastrophic system failure, since the processor removes itself from the system to
protect memory contents from erroneous accesses. Only an external reset operation can
restart a halted processor.
4.6.10 Address Error
An address error exception occurs when the processor attempts to access a word or long-
word operand or an instruction at an odd address. An address error is similar to an
internally generated bus error. The bus cycle is aborted, and the processor ceases current
processing and begins exception processing. The exception processing sequence is the
same as that for a bus error, including the information to be stacked, except that the
vector number refers to the address error vector. Likewise, if an address error occurs
during the exception processing for a bus error, address error, or reset, the processor is
halted.
4.6.11 Multiple Exceptions
When multiple exceptions occur simultaneously, they are processed according to a fixed
priority. Table 4-6 lists the exceptions, grouped by characteristics, with group 0 as the
highest priority. Within group 0, reset has highest priority, followed by address error and
then bus error. Within group 1, trace has priority over external interrupts, which in turn
takes priority over illegal instruction and privilege violation. Since only one instruction can
be executed at a time, no priority relationship applies within group 2.
MOTOROLA
Figure 4-7. Supervisor Stack Order for Bus or Address Error Exception
Freescale Semiconductor, Inc.
ADDRESS
For More Information On This Product,
LOWER
MC68306 USER'S MANUAL
Go to: www.freescale.com
15
R/W (READ/WRITE): WRITE = 0, READ = 1. I/N
(INSTRUCTION/NOT): INSTRUCTION = 0, NOT = 1.
PROGRAM COUNTER
ACCESS ADDRESS
5
R/W
INSTRUCTION REGISTER
4
STATUS REGISTER
I/N FUNCTION CODE
3
2
HIGH
LOW
HIGH
LOW
EC33
0
4- 21

Related parts for MC68306FC16B