KSZ8893MBL Micrel Inc, KSZ8893MBL Datasheet - Page 34

IC MANAGED SW 10/100 100-LFBGA

KSZ8893MBL

Manufacturer Part Number
KSZ8893MBL
Description
IC MANAGED SW 10/100 100-LFBGA
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8893MBL

Controller Type
Ethernet Switch Controller
Interface
MII, RMII, SNI
Voltage - Supply
3.1 V ~ 3.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LFBGA
Number Of Primary Switch Ports
3
Internal Memory Buffer Size
32
Operating Supply Voltage (typ)
3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Power Supply Type
Analog/Digital
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
3.5V
Operating Supply Voltage (min)
3.1V
Operating Temperature Classification
Commercial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-1603 - EVAL KIT EXPERIMENTAL KSZ8893MQL
Current - Supply
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
576-3090

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8893MBL
Manufacturer:
Micrel
Quantity:
1 272
Part Number:
KSZ8893MBL
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8893MBL TR
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8893MBLI
Manufacturer:
Micrel
Quantity:
2 022
Part Number:
KSZ8893MBLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8893MBLI
0
LinkMD Cable Diagnostics
The LinkMD feature utilizes time domain reflectometry (TDR) to analyze the cabling plant for common cabling
problems such as open circuits, short circuits and impedance mismatches.
LinkMD works by sending a pulse of known amplitude and duration down the MDI and MDI-X pairs and then
analyzes the shape of the reflected signal. Timing the pulse duration gives an indication of the distance to the
cabling fault with maximum distance of 200m and accuracy of +/- 2m. Internal circuitry displays the TDR
information in a user-readable digital format.
Note: Cable diagnostics are only valid for copper connections and do not support fiber optic operation.
Access
LinkMD is initiated by accessing registers {26,27} and {42,43}, the LinkMD Control/Status registers, for ports 1
and 2, respectively; and in conjunction with registers 29 and 45, Port Control Register 13, for ports 1 and 2,
respectively.
Alternatively, the MIIM PHY registers 0 and 29 can be used for LinkMD access.
Usage
The following is a sample procedure for using LinkMD with registers {26,27,29} on port 1.
1. Disable auto MDI/MDI-X by writing a ‘1’ to register 29, bit [2] to enable manual control over the differential pair
2. Start cable diagnostic test by writing a ‘1’ to register 26, bit [4]. This enable bit is self-clearing.
3. Wait (poll) for register 26, bit [4] to return a ‘0’, indicating cable diagnostic test is completed.
4. Read cable diagnostic test results in register 26, bits [6:5]. The results are as follows:
5. Get distance to fault by concatenating register 26, bit [0] and register 27, bits [7:0]; and multiplying the result
For port 2 and for the MIIM PHY registers, LinkMD usage is similar.
December 2007
used to transmit the LinkMD pulse.
The ‘11’ case, invalid test, occurs when the KSZ8893MQL/MBL is unable to shut down the link partner. In this
instance, the test is not run, since it would be impossible for the KSZ8893MQL/MBL to determine if the
detected signal is a reflection of the signal generated or a signal from another source.
by a constant of 0.4. The distance to the cable fault can be determined by the following formula:
D (distance to cable fault) is expressed in meters.
Concatenated value of registers 26 and 27 is converted to decimal before multiplying by 0.4.
The constant (0.4) may be calibrated for different cabling conditions, including cables with a velocity of
propagation that varies significantly from the norm.
00 = normal condition (valid test)
01 = open condition detected in cable (valid test)
10 = short condition detected in cable (valid test)
11 = cable diagnostic test failed (invalid test)
D (distance to cable fault) = 0.4 x {(register 26, bit [0]),(register 27, bits [7:0])}