AD5933YRSZ Analog Devices Inc, AD5933YRSZ Datasheet - Page 24

IC NTWK ANALYZER 12B 1MSP 16SSOP

AD5933YRSZ

Manufacturer Part Number
AD5933YRSZ
Description
IC NTWK ANALYZER 12B 1MSP 16SSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5933YRSZ

Resolution (bits)
12 b
Master Fclk
16.776MHz
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
Supply Voltage Range
2.7V To 5.5V
Operating Temperature Range
-40°C To +125°C
Digital Ic Case Style
SSOP
No. Of Pins
16
Frequency Max
0.1MHz
Termination Type
SMD
Pin Count
16
Screening Level
Automotive
Package Type
SSOP
Filter Terminals
SMD
Rohs Compliant
Yes
Communication Function
Network Analyzer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD5933EBZ - BOARD EVALUATION FOR AD5933
Tuning Word Width (bits)
-
Lead Free Status / Rohs Status
Compliant
Other names
AD5933BRSZ
Q2204656A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5933YRSZ
Manufacturer:
ADI
Quantity:
5 000
Part Number:
AD5933YRSZ
Manufacturer:
Fujitsu
Quantity:
500
Part Number:
AD5933YRSZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD5933
REGISTER MAP
Table 8.
Register
0x80
0x81
0x82
0x83
0x84
0x85
0x86
0x87
0x88
0x89
0x8A
0x8B
0x8F
0x92
0x93
0x94
0x95
0x96
0x97
CONTROL REGISTER (REGISTER ADDRESS 0x80,
REGISTER ADDRESS 0x81)
The AD5933 has a 16-bit control register (Register Address 0x80
and Register Address 0x81) that sets the AD5933 control
modes. The default value of the control register upon reset is
as follows: D15 to D0 reset to 0xA000 upon power-up.
The four MSBs of the control register are decoded to provide
control functions, such as performing a frequency sweep,
powering down the part, and controlling various other
functions defined in the control register map.
The user may choose to write only to Register Address 0x80 and
not to alter the contents of Register Address 0x81. Note that the
control register should not be written to as part of a block write
command. The control register also allows the user to program
the excitation voltage and set the system clock. A reset command
to the control register does not reset any programmed values
associated with the sweep (that is, start frequency, number of
increments, frequency increment). After a reset command, an
initialize with start frequency command must be issued to the
control register to restart the frequency sweep sequence (see
Figure 34).
Name
Control
Start frequency
Frequency increment
Number of increments
Number of settling time cycles
Status
Temperature data
Real data
Imaginary data
Rev. C | Page 24 of 44
Table 9. Control Register Map (D15 to D12)
D15
0
0
0
0
0
1
1
1
1
1
1
Table 10. Control Register Map (D10 to D9)
D10
0
0
1
1
D14
0
0
0
0
1
0
0
0
0
1
1
D9
0
1
0
1
Register Data
D15 to D8
D7 to D0
D23 to D16
D15 to D8
D7 to D0
D23 to D16
D15 to D8
D7 to D0
D15 to D8
D7 to D0
D15 to D8
D7 to D0
D7 to D0
D15 to D8
D7 to D0
D15 to D8
D7 to D0
D15 to D8
D7 to D0
D13
0
0
1
1
0
0
0
1
1
0
0
Range No.
1
4
3
2
D12
0
1
0
1
0
0
1
0
1
0
1
Function
No operation
Initialize with start frequency
Start frequency sweep
Increment frequency
Repeat frequency
No operation
Measure temperature
Power-down mode
Standby mode
No operation
No operation
Output Voltage Range
2.0 V p-p typical
200 mV p-p typical
400 mV p-p typical
1.0 V p-p typical
Function
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read/write
Read only
Read only
Read only
Read only
Read only
Read only
Read only