AD5933YRSZ Analog Devices Inc, AD5933YRSZ Datasheet - Page 30

IC NTWK ANALYZER 12B 1MSP 16SSOP

AD5933YRSZ

Manufacturer Part Number
AD5933YRSZ
Description
IC NTWK ANALYZER 12B 1MSP 16SSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5933YRSZ

Resolution (bits)
12 b
Master Fclk
16.776MHz
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
Supply Voltage Range
2.7V To 5.5V
Operating Temperature Range
-40°C To +125°C
Digital Ic Case Style
SSOP
No. Of Pins
16
Frequency Max
0.1MHz
Termination Type
SMD
Pin Count
16
Screening Level
Automotive
Package Type
SSOP
Filter Terminals
SMD
Rohs Compliant
Yes
Communication Function
Network Analyzer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD5933EBZ - BOARD EVALUATION FOR AD5933
Tuning Word Width (bits)
-
Lead Free Status / Rohs Status
Compliant
Other names
AD5933BRSZ
Q2204656A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5933YRSZ
Manufacturer:
ADI
Quantity:
5 000
Part Number:
AD5933YRSZ
Manufacturer:
Fujitsu
Quantity:
500
Part Number:
AD5933YRSZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD5933
READ OPERATIONS
The AD5933 uses two I
block read.
Receive Byte
In the AD5933, the receive byte protocol is used to read a single
byte of data from a register address whose address has previously
been set by setting the address pointer.
In this operation, the master device receives a single byte from a
slave device as follows (see Figure 39):
1.
2.
3.
4.
5.
6.
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
read bit (high).
The addressed slave device asserts an acknowledge on SDA.
The master receives a data byte.
The master asserts a no acknowledge on SDA (the slave
needs to check that master has received data).
The master asserts a stop condition on SDA and the
transaction ends.
S
S
ADDRESS
ADDRESS
SLAVE
SLAVE
Figure 39. Reading Register Data
2
C read protocols: receive byte and
W
R
A
A
BLOCK
REGISTER
READ
DATA
A
A
BYTES READ
NUMBER
P
Figure 40. Performing a Block Read
A
Rev. C | Page 30 of 44
S
ADDRESS
SLAVE
Block Read
In this operation, the master device reads a block of data from a
slave device (see Figure 40). The start address for a block read
must previously have been set by setting the address pointer.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. The slave asserts an acknowledge on SDA.
11. The master receives the data bytes.
12. The master asserts an acknowledge on SDA after each
13. A no acknowledge is generated after the last byte to signal
14. The master asserts a stop condition on SDA to end the
R
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
write bit (low).
The addressed slave device asserts an acknowledge on SDA.
The master sends a command code (1010 0001) that tells
the slave device to expect a block read.
The slave asserts an acknowledge on SDA.
The master sends a byte-count data byte that tells the slave
how many data bytes to expect.
The slave asserts an acknowledge on SDA.
The master asserts a repeat start condition on SDA. This is
required to set the read bit high.
The master sends the 7-bit slave address followed by the
read bit (high).
data byte.
the end of the read.
transaction.
A
BYTE 0
A
BYTE 1
A
BYTE 2
A
P

Related parts for AD5933YRSZ