PEB24911HV13 Lantiq, PEB24911HV13 Datasheet - Page 133

no-image

PEB24911HV13

Manufacturer Part Number
PEB24911HV13
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB24911HV13

Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB24911HV13
Manufacturer:
RENESAS
Quantity:
3 897
MFILT
Reset value: 14
M56
FILTER
M4
Filter
Data Sheet
M56 FILTER
7
controls the validation mode of the spare bits (M51, M52, M61) on a per bit
base. Approved M5, M6 bit changes are reported to the system interface by
a MON-2 message
X0 =
X1 =
3-bit field which controls the validation mode of the M4 bits on a per bit
base. Approved M4 bit changes are reported to the system interface by a
MON-2 message.
– Bit 3 and 4 determine the filter algorithm that is applied for the triggering
– Bit 5 controls whether the forwarding of M4 bits to the internal state
Note: Bellcore TR-NWT-397 (1993) requires to apply TLL to the M4 bits
x00 =
x01 =
x10 =
of a MON-2 message
machine shall be approved by default by TLL or by the same filtering
mode as selected for the forwarding to the system environment
H
before M4 bit changes are processed by the state machine
6
Apply same filter to M5 and M6 bit data as programmed for M4 bit
data
On Change
if a change of the M5, M6 bit status has occurred a MON-2
message will be issued
On Change
if a change of the M4 bit status has occurred it will be indicated to
the system by a MON-2 message
TLL coverage of M4 bit data
a change of M4 bit data is only passed on if it has been received in
three consecutive frames
CRC coverage of M4 bit data
a change of M4 bit data is passed on if no CRC violation has been
detected
5
M4 FILTER
4
read*
123
)
/write
3
2
Register Description
EOC FILTER
Address: 01
1
PEF 24911
2001-07-16
0
H

Related parts for PEB24911HV13