3.8.1
Figure 20
system interface and when it is reported to the state machine:
• towards the system interface MON-2 messages might be sent after one complete
• whereas towards the state machine M4-bit changes (ACT, SAI) are instantly passed
Figure 20
Data Sheet
U-superframe was received,
on as soon as they were approved by TLL (default setting in register MFILT, see
“MFILT - M-Bit Filter Options” on Page
In context to
at the end of basic frame #1 instead at the end of basic frame #8.
1) CRCON = 1: CRC
2) CRCON = 0: TLL
3) MON12: MFILT = 14
illustrates the point of time when a detected M4 bit change is reported to the
M4 Bit Reporting to State Machine
change
SF1
BF1
SF1
BF1
SF1
BF1
M4 Bit Report Timing
change
change
Figure 20
H
SM / on-change
SM / CRC & on-change
: TLL
this means that a verified ACT bit change is already reported
SM / CRCR on-change
CRC
MON2
Nearend
MON2
MON2
SF2
SF2
BF1
SF2
BF1
(SF1)
no change
no change
41
122).
MON2
CRC
SM & MON2
Farend
MON2
(SF1)
SF3
SF3
SF3
BF1
Functional Description
no change
no change
SM
SM
PEF 24911
m4tim2sm_a.emf
2001-07-16