peb20320 Infineon Technologies Corporation, peb20320 Datasheet - Page 17

no-image

peb20320

Manufacturer Part Number
peb20320
Description
Multichannel Network Interface Controller For Hdlc
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB20320
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB20320
Manufacturer:
HP
Quantity:
5 510
Part Number:
peb20320H
Manufacturer:
SIEMENS
Quantity:
343
Part Number:
peb20320H
Manufacturer:
SIEMENS
Quantity:
672
Part Number:
peb20320H V3.2
Manufacturer:
ST
Quantity:
94
Part Number:
peb20320H-V34
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb20320HV3.2R
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Pin Definitions and Functions (cont’d)
Pin No.
P-MQFP-160-1
82
79
81
User’s Manual
Symbol
HOLD
BR
HLDA
BG
BGACK
PM
Output (O)
Input (I)
I/O
I/O
O
I
I
I
17
Function
Bus Hold Request (Intel bus mode)
This signal is driven high when the
MUNICH32 requests the control of the
bus.
Bus Request (Motorola bus mode)
This signal is driven low when the
MUNICH32 requests the control of the bus
and is interpreted when another
MUNICH32 wants to be the bus master.
Bus Hold Acknowledge (Intel bus mode)
This active high signal indicates that the
processor has released the control of the
bus. The MUNICH32 starts the bus cycles.
Bus Grant (Motorola bus mode)
This active low signal indicates that the
MUNICH32 may assume the bus
mastership.
Bus Grant Acknowledge (Motorola bus
mode)
This signal is driven low by the device,
when it has become the bus master. It also
informs the MUNICH32 whether another
device is bus master.
Parity Mode (Intel bus mode)
This signal has to be strapped to
before reset to enable the Intel parity
mode or to
Intel non-parity mode. It has to be left
strapped during reset and operation.
V
SS
before reset to enable the
Introduction
PEB 20320
V
DD
01.2000