M25PX80-VMP6TG NUMONYX, M25PX80-VMP6TG Datasheet - Page 23

no-image

M25PX80-VMP6TG

Manufacturer Part Number
M25PX80-VMP6TG
Description
IC FLASH 8MBIT 75MHZ 8VFQFPN
Manufacturer
NUMONYX
Series
Forté™r
Datasheet

Specifications of M25PX80-VMP6TG

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
8M (1M x 8)
Speed
75MHz
Interface
SPI, 3-Wire Serial
Voltage - Supply
2.3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-VFQFN, 8-VFQFPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
M25PX80-VMP6TGTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M25PX80-VMP6TG
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M25PX80-VMP6TG
Manufacturer:
ST
0
Company:
Part Number:
M25PX80-VMP6TG
Quantity:
10
Part Number:
M25PX80-VMP6TGT0
Manufacturer:
ST
0
Part Number:
M25PX80-VMP6TGTO
Manufacturer:
PHILIPS
Quantity:
39 250
Table 6.
6.4
Manufacturer identification
See
Any Read Identification (RDID) instruction while an Erase or Program cycle is in progress, is
not decoded, and has no effect on the cycle that is in progress.
The Read Identification (RDID) instruction should not be issued while the device is in Deep
Power-down mode.
The device is first selected by driving Chip Select (S) Low. Then, the 8-bit instruction code
for the instruction is shifted in. After this, the 24-bit device identification, stored in the
memory, the 8-bit CFD length followed by 16 bytes of CFD content will be shifted out on
Serial Data output (DQ1). Each bit is shifted out during the falling edge of Serial Clock (C).
The instruction sequence is shown in
The Read Identification (RDID) instruction is terminated by driving Chip Select (S) High at
any time during data output.
When Chip Select (S) is driven High, the device is put in the Standby Power mode. Once in
the Standby Power mode, the device waits to be selected, so that it can receive, decode and
execute instructions.
Read Identification (RDID) data-out sequence
Figure 9.
Read Status Register (RDSR)
The Read Status Register (RDSR) instruction allows the Status Register to be read. The
Status Register may be read at any time, even while a Program, Erase or Write Status
Register cycle is in progress. When one of these cycles is in progress, it is recommended to
check the Write In Progress (WIP) bit before sending a new instruction to the device. It is
also possible to read the Status Register continuously, as shown in
20h
Section 12: Ordering information on page 59
Read Identification (RDID) instruction sequence and data-out sequence
Memory type
71h
Device identification
Memory capacity
Figure
14h
9.
for CFD programmed devices.
CFD length
10h
Figure
UID
10.
CFD content
16 bytes
23/60

Related parts for M25PX80-VMP6TG