MAX16070ETL+ Maxim Integrated Products, MAX16070ETL+ Datasheet - Page 13

no-image

MAX16070ETL+

Manufacturer Part Number
MAX16070ETL+
Description
IC SYSTEM MANAGER 12CH 40-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16070ETL+

Applications
Power Supply Monitor
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN Exposed Pad, 40-HVQFN, 40-SQFN, 40-DHVQFN
Product
Current Monitors
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Accuracy
2.5 %
Sense Voltage (max)
14 V
Supply Current (max)
14 mA
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Once EN is above its threshold and the software-enable
bit is set, a boot-up delay occurs before monitoring
begins. This delay is configured in register r77h[3:0] as
shown in Tables 2 and 3.
The current-sense inputs, CSP/CSM, and a current-
sense amplifier facilitate power monitoring (see Figure
4). The voltage on CSP relative to GND is also monitored
by the ADC when the current-sense amplifier is enabled
with r47h[0]. The conversion results are located in regis-
ters r19h and r1Ah (see Table 6). There are two select-
able voltage ranges for CSP set by r47h[1], see Table
4. Although the voltage can be monitored over SMBus
or JTAG, this voltage has no threshold comparators and
cannot trigger any faults. Regarding the current-sense
amplifier, there are four selectable ranges and the ADC
output for a current-sense conversion is:
where X
r18h, V
sense voltage gain set by r47h[3:2].
Table 2. Boot-Up Delay Register
Table 3. Boot-Up Delay Values
12-Channel/8-Channel, Flash-Configurable System
REGISTER
ADDRESS
77h
SENSE
ADC
X
ADC
is the 8-bit decimal ADC result in register
Internal Current-Sense Amplifier
is V
= (V
Managers with Nonvolatile Fault Registers
______________________________________________________________________________________
CSP
SENSE
ADDRESS
FLASH
277h
- V
CODE
x A
CSM,
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
V
)/1.4V x (2
and A
BIT RANGE
Boot-Up Delay
V
[3:0]
[7:0]
is the current-
8
- 1)
Boot-up delay
Reserved
In addition, there are two programmable current-sense
trip thresholds: primary overcurrent and secondary over-
current. For fast fault detection, the primary overcurrent
threshold is implemented with an analog comparator
connected to the internal OVERC signal. The OVERC
signal can be output on one of the GPIO_s. See the
General-Purpose Inputs/Outputs section for configur-
ing the GPIO_ to output the OVERC signal. The primary
threshold is set by:
where I
the threshold set by r47h[3:2], and R
of the sense resistor. See Table 4 for a description of
r47h. OVERC depends only on the primary overcurrent
threshold. The secondary overcurrent threshold is imple-
mented through ADC conversions and digital compari-
son set by r6Ch. The secondary overcurrent threshold
includes programmable time delay options located in
r73h[6:5]. Primary and secondary current-sense faults
are enabled/disabled through r47h[0].
TH
is the current threshold to be set, V
DESCRIPTION
I
TH
= V
VALUE
100ms
200ms
400ms
800ms
500Fs
10ms
12ms
25ms
25Fs
1ms
2ms
3ms
4ms
6ms
8ms
1.6s
CSTH
/R
SENSE
SENSE
is the value
CSTH
13
is