MAX16070ETL+ Maxim Integrated Products, MAX16070ETL+ Datasheet - Page 25

no-image

MAX16070ETL+

Manufacturer Part Number
MAX16070ETL+
Description
IC SYSTEM MANAGER 12CH 40-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16070ETL+

Applications
Power Supply Monitor
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN Exposed Pad, 40-HVQFN, 40-SQFN, 40-DHVQFN
Product
Current Monitors
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Accuracy
2.5 %
Sense Voltage (max)
14 V
Supply Current (max)
14 mA
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Table
If a GPIO_ is configured as an open-drain EXTFAULT
input/output, and EXTFAULT is pulled low by an external
circuit, bit r1Ch[5] is set.
The SMB Alert bit is set if the MAX16070/MAX16071
have asserted the SMBus Alert output. Clear by writing a
‘1’. See SMBALERT section for more details.
During normal operation, a fault condition can be con-
figured to store fault information in the flash memory by
setting the appropriate critical fault enable bits. Set the
appropriate critical fault enable bits in registers r6Eh to r72h
(see Table 14) for a fault condition to trigger a critical fault.
Table
12-Channel/8-Channel, Flash-Configurable System
REGISTER
ADDRESS
FLASH ADDRESS
72h
14. Critical Fault Configuration (continued)
15. Nonvolatile Fault Log Registers
200h
201h
202h
ADDRESS
FLASH
Managers with Nonvolatile Fault Registers
272h
______________________________________________________________________________________
BIT RANGE
[7:6]
RANGE
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[7:6]
BIT
[0]
[1]
[2]
[3]
[4]
[5]
Reserved
Fault log triggered on MON1
Fault log triggered on MON2
Fault log triggered on MON3
Fault log triggered on MON4
Fault log triggered on MON5
Fault log triggered on MON6
Fault log triggered on MON7
Fault log triggered on MON8
Fault log triggered on MON9
Fault log triggered on MON10
Fault log triggered on MON11
Fault log triggered on MON12
Fault log triggered on overcurrent
Fault log triggered on EXTFAULT
Not used
1 = Fault log triggered when MON9 is above/below the early threshold warning
1 = Fault log triggered when MON10 is above/below the early threshold warning
1 = Fault log triggered when MON11 is above/below the early threshold warning
1 = Fault log triggered when MON12 is above/below the early threshold warning
1 = Fault log triggered when overcurrent early threshold is exceeded
Reserved, must be set to ‘1’
Reserved
Critical Faults
Logged fault information is stored in flash registers r200h
to r20Fh (see Table 15). After fault information is logged,
the flash is locked and must be unlocked to enable a
new fault log to be stored. Write a ‘0’ to r8Ch[1] to unlock
the fault flash. Fault information can be configured to
store ADC conversion results and/or fault flags in reg-
isters. Select the critical fault configuration in r6Dh[1:0].
Set r6Dh[1:0] to ‘11’ to turn off the fault logger. All stored
ADC results are 8 bits wide.
DESCRIPTION
DESCRIPTION
25