KSZ8993MI Micrel Inc, KSZ8993MI Datasheet - Page 6

IC SWITCH 10/100 W/TXRX 128PQFP

KSZ8993MI

Manufacturer Part Number
KSZ8993MI
Description
IC SWITCH 10/100 W/TXRX 128PQFP
Manufacturer
Micrel Inc
Datasheets

Specifications of KSZ8993MI

Applications
*
Mounting Type
Surface Mount
Package / Case
128-MQFP, 128-PQFP
Number Of Primary Switch Ports
3
Internal Memory Buffer Size
32
Operating Supply Voltage (typ)
1.8/2.5/3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII/SNI
Power Supply Type
Analog/Digital
Package Type
PQFP
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Pin Count
128
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
1.89/3.465V
Operating Supply Voltage (min)
1.71/3.135V
Power Dissipation
800mW
Supply Current
0.1/0.19A
Operating Temperature Classification
Industrial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
576-2124
KSZ8993MI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8993MI
Manufacturer:
MICREL
Quantity:
1 900
Part Number:
KSZ8993MI
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8993MI
Manufacturer:
MICREL
Quantity:
1 000
Part Number:
KSZ8993MI
Manufacturer:
KENDIN
Quantity:
20 000
Contents
List of Figures .........................................................................................................................................9
List of Tables...........................................................................................................................................9
Pin Description and I/O Assignment...................................................................................................10
Pin Configuration..................................................................................................................................20
Functional Description .........................................................................................................................21
Functional Overview: Physical Layer Transceiver ............................................................................21
Functional Overview: MAC and Switch ..............................................................................................27
Advanced Switch Functions ................................................................................................................34
MII Management (MIIM) Registers .......................................................................................................45
Micrel, Inc.
October 2008
100BASE-TX Transmit.........................................................................................................................................................21
100BASE-TX Receive ..........................................................................................................................................................21
PLL Clock Synthesizer........................................................................................................................................................22
Scrambler/De-scrambler (100BASE-TX Only) ...................................................................................................................22
100BASE-FX Operation.......................................................................................................................................................22
100BASE-FX Signal Detection............................................................................................................................................22
100BASE-FX Far End Fault.................................................................................................................................................22
10BASE-T Transmit .............................................................................................................................................................23
10BASE-T Receive ..............................................................................................................................................................23
Power Management.............................................................................................................................................................23
MDI /MDI-X Auto Crossover................................................................................................................................................23
Auto Negotiation .................................................................................................................................................................25
Address Lookup ..................................................................................................................................................................27
Learning ...............................................................................................................................................................................27
Migration ..............................................................................................................................................................................27
Aging ....................................................................................................................................................................................27
Forwarding...........................................................................................................................................................................27
Switching Engine ................................................................................................................................................................30
MAC Operation ....................................................................................................................................................................30
MII Interface Operation........................................................................................................................................................31
SNI (7-Wire) Operation ........................................................................................................................................................32
MII Management Interface (MIIM) .......................................................................................................................................32
Serial Management Interface (SMI) ....................................................................................................................................33
Spanning Tree Support.......................................................................................................................................................34
Upstream Special Tagging Mode .......................................................................................................................................35
IGMP Support ......................................................................................................................................................................36
Port Mirroring Support........................................................................................................................................................36
IEEE 802.1Q VLAN Support ................................................................................................................................................36
QoS Priority Support...........................................................................................................................................................37
Rate Limiting Support .........................................................................................................................................................39
Configuration Interface .......................................................................................................................................................39
Loopback Support...............................................................................................................................................................44
Straight Cable ................................................................................................................................................................23
Crossover Cable ............................................................................................................................................................25
Inter Packet Gap (IPG) ..................................................................................................................................................30
Back-Off Algorithm.........................................................................................................................................................30
Late Collision .................................................................................................................................................................30
Illegal Frames ................................................................................................................................................................30
Flow Control...................................................................................................................................................................30
Half-Duplex Backpressure .............................................................................................................................................30
Broadcast Storm Protection ...........................................................................................................................................31
“IGMP” Snooping ...........................................................................................................................................................36
“Multicast Address Insertion” in the Static MAC Table...................................................................................................36
I
I
SPI Slave Serial Bus Configuration ...............................................................................................................................40
2
2
C Master Serial Bus Configuration ..............................................................................................................................39
C Slave Serial Bus Configuration ................................................................................................................................40
6
M9999-020606
KSZ8993M/ML

Related parts for KSZ8993MI