CDB53L21 Cirrus Logic Inc, CDB53L21 Datasheet - Page 7

no-image

CDB53L21

Manufacturer Part Number
CDB53L21
Description
BOARD EVAL FOR CS53L21 ADC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB53L21

Number Of Adc's
2
Number Of Bits
24
Sampling Rate (per Second)
96k
Data Interface
Serial
Inputs Per Adc
3 Single Ended
Input Range
±2.5 V
Power (typ) @ Conditions
22.45mW @ 48kSPS, 2.5 V
Voltage Supply Source
Analog and Digital
Operating Temperature
-10°C ~ 70°C
Utilized Ic / Part
CS53L21
Product
Audio Modules
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1550
DS700DB1
2. SOFTWARE MODE CONTROL
The CDB53L21 may be used with the Microsoft Windows-based FlexGUI graphical user interface, allowing software
control of the CS53L21 and FPGA registers. The latest control software may be downloaded from
www.cirrus.com/msasoftware. Step-by-step instructions for setting up the FlexGUI are provided as follows:
For standard setup:
For quick setup, the CDB53L21 may, alternatively, be configured by loading a predefined sample script file:
To create personal scripts files:
1. Download and install the FlexGUI software as instructed on the Website.
2. Connect and apply power to the +5.0 V binding post.
3. Connect the CDB to the host PC using either a 9-pin serial or USB cable.
4. Launch the Cirrus FlexGUI. Once the GUI is launched successfully, all registers are set to their default reset
5. Enable the CS53L21 by engaging the “Enable CS53L21” push button.
6. Refresh the GUI by clicking on the “Update” button. The default state of all registers are now visible.
7. Engage and then disengage the “Power Down” push button in the “ADC Basic Configurations” group. This
8. Set up the signal routing in the “General Configurations” tab as desired.
9. Set up the CS53L21 in the “ADC Configuration”, “ADC Volume Controls” or “Mix Volume Controls” tab as
10. Begin evaluating the CS53L21.
11. On the File menu, click "Restore Board Registers..."
12. Browse to Boards\CDB53L21\Scripts\.
13. Choose any one of the provided scripts to begin evaluation.
14. On the File menu, click "Save Board Registers..."
15. Enter any name that sufficiently describes the created setup.
16. Choose the desired location and save the script.
17. To load this script, follow the instructions from step
state.
performs the necessary write sequence to the CS53L21 for Software Mode operation.
desired.
11
above.
CDB53L21
7