H5CX-L8-N AC100-240 Omron, H5CX-L8-N AC100-240 Datasheet - Page 16

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-L8-N AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Time Range
0.001s-9999hr
Power Consumption
6.2VA
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
100VAC
Connector Type
8-Pin Socket
Signal Input Type
PNP/NPN
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXL8NAC100240
Z2999
16
H5CX-A@-N/-L@-N
Timer
• Change to Function Setting Mode.
From next page
Step2
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Run mode
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
Power ON
To next page
Settings that cannot be performed with the DIP switch are performed with the operation keys.
Time range
Timer mode
Output modes
Output time
Input signal
NPN/PNP
input
Display color
Instantaneous/
time-limit
3 s min.
3 s min.
Function setting mode
* 1
* 2
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated in
Set the time range using the
Set the timer mode using the
Set the output mode using the
Set each digit for the output time using the corresponding
Set the input signal width using the
Set the NPN/PNP mode using the
Set the display color using the
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the
Note: Only modes A-2, b, E, and Z can be selected for models with instantaneous
(If the output time is set to 0.00,
Note: Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only.
Note: Not displayed for models with instantaneous contact outputs.
Note: Only displayed for the H5CX-A@ and H5CX-A11@.
Note: Displayed only for models with terminal screws (H5CX-A@).
Note: Displayed only for models with instantaneous contact outputs.
(Instantaneous) (Time-limit)
(NPN input)
(Output hold)
For details, refer to the Time Range List.
(A)
a
(20ms)
(UP)
20ms
npn
red
1c1c
hold
(Red)
up
contact outputs.
(A-1)
a-1
s
(PNP input)
For details on operations in run mode, refer to page 19.
(DOWN)
(0.01s)
0.01
grn
(Green)
down
pnp
1ms
(1ms)
2c
(A-2)
a-2
Keys.
~
99.99
(99.99s)
s
(Orange)
org
(A-3)
a-3
hold
(Red-green)
r-g
(b)
b
s
keys.
keys.
is displayed.)
keys.
keys.
b-1
(b-1)
……
(Green-red)
keys.
keys.
g-r
(d)
d
(Red-orange) (Orange-red) (Green-orange)(Orange-green)
r-o
(E)
e
h
(F)
f
will not be displayed.
o-r
keys.
(Z)
z
s
(S)
s
g-o
Time Range List
o-g
Display
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to
99 min 59 s
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
1 h to 9999 h
0.001 s to
9.999 s
Set Value