H5CX-L8-N AC100-240 Omron, H5CX-L8-N AC100-240 Datasheet - Page 26

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-L8-N AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Time Range
0.001s-9999hr
Power Consumption
6.2VA
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
100VAC
Connector Type
8-Pin Socket
Signal Input Type
PNP/NPN
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXL8NAC100240
Z2999
26
H5CX-A@-N/-L@-N
Twin Timer
To switch to twin timer operation, use the procedure given below. For details, refer to page 31.
• Change to Function Setting Mode.
Step3
To next page
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Power ON
Run mode
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
From next page
Settings that cannot be performed with the DIP switch are performed with the operation keys.
OFF time
range
ON time
range
Timer mode
ON/OFF
start mode
Input signal
width
NPN/PNP
input
Display
color
Instantaneous/
time-limit
3 s min.
3 s min.
Function setting mode
*1
*2
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated in
Set the OFF time range using the
Set the ON time range using the
Set the timer mode using the
Set the twin timer output mode using the
Set the input signal width using the
Set the NPN/PNP input mode using the
Set the display color using the
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the
Note: Only Flicker OFF Start 1 or Flicker ON Start 1 can be selected for the H5CX-L8E@.
Note: Not displayed for models with instantaneous contact outputs.
Note: Displayed only for the H5CX-A @ and H5CX-A11@.
Note: Displayed only for models with terminal screws (H5CX-A @).
Note: Displayed only for models with instantaneous contact outputs.
(Instantaneous) (Time-limit)
(
(NPN input)
For details, refer to Time Range List.
For details, refer to Time Range List.
OFF start 1
(20 ms)
(UP)
toff
20ms
npn
red
1c1c
Flicker
(Red)
up
s
s
(PNP input)
) (
For details on operations in run mode, refer to page 28.
(DOWN)
grn
(Green)
pnp
down
On Start 1
(1 ms)
1ms
Flicker
ton
2c
Keys.
s
s
(Orange)
org
) (
OFF start 2
tof1
Flicker
(Red-green)
r-g
s
s
) (
keys.
keys.
On Start 2
keys.
Flicker
ton1
keys.
……
……
(Green-red)
keys.
g-r
keys.
keys.
)
(Red-orange)
r-o
h
h
(Orange-red)
will not be displayed.
o-r
s
s
(Green-orange) (Orange-green)
g-o
Time Range List
o-g
Display
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to
99 min 59 s
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
1 h to 9999 h
0.001 s to
9.999 s
Set Value

Related parts for H5CX-L8-N AC100-240