MC9S08DZ96MLF Freescale Semiconductor, MC9S08DZ96MLF Datasheet - Page 152

no-image

MC9S08DZ96MLF

Manufacturer Part Number
MC9S08DZ96MLF
Description
MCU 8BIT 96K FLASH 48-LQFP
Manufacturer
Freescale Semiconductor
Series
HCS08r
Datasheets

Specifications of MC9S08DZ96MLF

Core Processor
HCS08
Core Size
8-Bit
Speed
40MHz
Connectivity
CAN, I²C, LIN, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
39
Program Memory Size
96KB (96K x 8)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
6K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 16x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 125°C
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S08DZ96MLF
Manufacturer:
FREESCALE
Quantity:
3 210
Part Number:
MC9S08DZ96MLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S08DZ96MLF
Manufacturer:
FREESCALE
Quantity:
3 210
Chapter 7 Central Processor Unit (S08CPUV5)
The RTC instruction is used to terminate subroutines invoked by a CALL instruction. RTC unstacks the
PPAGE value and the return address, the queue is refilled, and execution resumes with the next instruction
after the corresponding CALL.
The actual sequence of operations that occur during execution of RTC is:
Since the return operation is implemented as a single uninterruptable CPU instruction, the RTC can be
executed from anywhere in memory, including from a different page of extended memory in the overlay
window.
The CALL and RTC instructions behave like JSR and RTS, except they have slightly longer execution
times. Since extra execution cycles are required, routinely substituting CALL/RTC for JSR/RTS is not
recommended. JSR and RTS can be used to access subroutines that are located outside the program overlay
window or on the same memory page. However, if a subroutine can be called from other pages, it must be
terminated with an RTC. In this case, since RTC unstacks the PPAGE value as well as the return address,
all accesses to the subroutine, even those made from the same page, must use CALL instructions.
152
1. The return value of the 8-bit PPAGE register is pulled from the stack.
2. The 16-bit return address is pulled from the stack and loaded into the PC.
3. The return PPAGE value is written to the PPAGE register.
4. The queue is refilled and execution begins at the new address.
MC9S08DZ128 Series Data Sheet, Rev. 1
Freescale Semiconductor

Related parts for MC9S08DZ96MLF