SC16C751BIBS,151 NXP Semiconductors, SC16C751BIBS,151 Datasheet - Page 18

IC UART SINGLE W/FIFO 24-HVQFN

SC16C751BIBS,151

Manufacturer Part Number
SC16C751BIBS,151
Description
IC UART SINGLE W/FIFO 24-HVQFN
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C751BIBS,151

Features
Programmable
Number Of Channels
1, UART
Fifo's
64 Byte
Voltage - Supply
2.5V, 3.3V, 5V
With Auto Flow Control
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Package / Case
24-VQFN Exposed Pad, 24-HVQFN, 24-SQFN, 24-DHVQFN
Voltage
2.5 V, 3.3 V, 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
935284741151
SC16C751BIBS-S
SC16C751BIBS-S
NXP Semiconductors
SC16C751B_2
Product data sheet
7.6 Modem Control Register (MCR)
This register controls the interface with the modem or a peripheral device.
Table 16.
The flow control can be configured by programming MCR[1] and MCR[5] as shown in
Table
Table 17.
Bit
7
6
5
4
3:2
1
0
MCR[5] (AFE)
1
1
0
17.
Symbol
MCR[7]
MCR[6]
MCR[5]
MCR[4]
MCR[3:2]
MCR[1]
MCR[0]
Modem Control Register bits description
Flow control configuration
Description
reserved; set to 0
reserved; set to 0
AFE. This bit is the auto flow control enable. When this bit is set, the auto
flow control is enabled.
Loopback. Enable the local Loopback mode (diagnostics). In this mode the
transmitter output (TX) and the receiver input (RX), CTS are disconnected
from the SC16C751B I/O pins. Internally the modem data and control pins
are connected into a loopback data configuration (see
mode, the receiver and transmitter interrupts remain fully operational. The
Modem Control Interrupts are also operational, but the interrupts’ sources
are switched to the lower four bits of the Modem Control. Interrupts continue
to be controlled by the IER register.
reserved
RTS
reserved
Rev. 02 — 10 October 2008
logic 0 = disable Loopback mode (normal default condition)
logic 1 = enable local Loopback mode (diagnostics)
logic 0 = force RTS output to a logic 1 (normal default condition)
logic 1 = force RTS output to a logic 0
MCR[1] (RTS)
1
0
X
5 V, 3.3 V and 2.5 V UART with 64-byte FIFOs
Flow configuration
auto RTS and CTS enabled
auto CTS only enabled
auto RTS and CTS disabled
SC16C751B
Figure
© NXP B.V. 2008. All rights reserved.
4). In this
18 of 32